� / <br /> �/:,_ G��t <br /> cr�'v or r:vrar�••r <br /> BUILDING DEPAR7'P�iGN'1' <br /> PLAN CORRECTION SNEET <br /> DATE Febrnary 21 19A4 USE ___ <br /> OIVNLR Standard Pacific NW Coro l�S?i ZONIAIG _ <br /> CONTRACTOR Same PIRE ZONE; <br /> ARCItITECT OCCUPANCT GROUP <br /> .JOB SITB ADDRESS Lot 2Q� Firever OCC'UPAtJT LOAD <br /> TYPG OP CONSTRUCTION PLAN CHECK N0. 84/12984 <br /> in response to your application f.or a permit, your plans and specifications <br /> h:�ve hecn examined and you are advised that the issuance oE si permit is <br /> tiaithheld for the reasons hereinafter set fortli . NOTE CARI:I�ULL�f : Ans�aer <br /> questions ati3 make explanations Uv correctin� original plans , and neia <br /> plans must be submitted to the Building Inspe:tion Department . ('l'li-is slieet <br /> must be returneJ with original plans and specifications or they �vi.1.1 be <br /> [iled as new business . ) <br /> Item No . UNIFORM I�UILDING CODG 1979 F:DITION C011L• SHC . <br /> �i'� 1 . Footing under south end of 6 x 14 requires reinforcing cr a � <br /> different shape. � <br /> �: 2. How is 2 x t; ledger attached to well in Detail 7 Sheet 5? <br /> { <br /> v <br /> 3. Provide means of venting the upper end of each rafter space � <br /> above the Family Room (and Garage^) in order to have cross �; <br /> vertilation. 32�5(c) " <br /> � 4. Garage ceiling to be 5/8 Type X gypsum wall board. <br /> (Note 10, Sfieet 2 isn't clear.) , <br /> � � <br /> 5. What is beam size over opening between Living Foom and � . , j� H �- <br /> Dining Roort�? �1Yi� .- ���. �. ;, �.(/. „r .,_ �^�f:� . � �,�rc-��, � �� � �b. U7C <br /> ✓ 6. 3-i/8" x 9" glulam over railing at BR corridor is over- �' ;- <br /> stressed even considering the 15,", increase allowed 'oy <br /> Section 2504(c)4i . <br /> � <br /> � ' 7. Qeam cver bay window in Unfinished Space can be Doug Fir '-`1 ,-, ' <br /> but not Hem Fir �l . �' <br /> � : <br /> � : <br /> i 8. All exterior footings to be minimum 18" below grade. � ` <br /> (See Note 9 Sheet 1 . ) <br />` „ 9. Exhaust fan is required in main floor Dath capab!e of _ <br /> providing 5 air changes per hour. 1205(a) `` <br /> � . . <br /> r; <br /> Page � of � _ - <br />