COMPLIANCE " ' / � + • �
<br /> HEDUIHED �
<br /> INSPECTION
<br /> APPROVED IMPORTANT: Please supply Informatlon In the shaded boxes and check the approprlate
<br /> � clrcles.Dlsregard Sopics ihat don't describe your bulldinp or equlpment.�QI place
<br /> checks In the two left columns.
<br /> . � • ,
<br /> ❑ ❑ 5 E�cterior slab Insulatlon, ii not focated on the interior, shall be R-10 (Table 5-1,6-1).
<br /> p � s Exterlor slab Insulatlon materlal, il present,shall approved for below grade use
<br /> ❑ ❑ (x�i Walls,Jnciuding rim jo�ts,shaH he Insula3ed without com�ressioa ta{Tabfe 6-2}: , , �
<br /> �fi-f5 batt(Options l,fg :(�R-19 (Opilon AI, IV,V, U! Vlq
<br /> ❑ ❑ Qinterlor beiow grade vralis shalt be 1nstilated without compresslon lo (Tahle B•2�:';
<br /> (�H•15 (Options I, lf� �A•18{Optionsllt,'IV,V,VI,VII) '
<br /> ❑ ❑ a Vaulted ceilinps shali be tnsulated withoui campr¢ssion to A-30(Tabie 6-2,Atl opt�Ons)
<br /> ❑ ❑ Qo �kylipht wall Insulation is fnstalled and equivalent to the required wall R-values above.
<br /> ❑ ❑ i Yapoc retarders shait be installed toward the warrn suHace as represente8 betaM, (5�2.L8);,
<br /> Select ona vption#or flnors,walts,and approp�late.celpngs:
<br /> Floors: Plywood W1 exteriur gNe �,t�oly(a 4 Mil) (� Backecl bF�tts'.
<br /> 1Nalls: Poiy plastl�(x;4 Mil� (� Face-stapted, oackr� batts ', �}Fh'A Ipafnt
<br /> Ceiifngs: Not'required where veMi�ation space averages>72"abuve(n�latlon,
<br /> Kece stapted badced 6atts �Poly plastic (z 4 mig (� [?VA p2iM '
<br /> ❑ ❑ 2 Heating system aHtclency and slzing requfremertts shall be met as reprBsented below:
<br /> ❑ ❑ � Heat Pump etflclency shatl 6e mei underthe iollowln0 compilance path.,(S.503.dj;
<br /> �Splft systam,atr souroe heat pumpi HSPPZ 6.8, COP>3.0
<br /> Q Single packa9e, au souroe heat pump:HSPf z 6.6, COP >3A '
<br /> , Q Water sourCe t�eat pump:COP z 3.8
<br /> � Ground source heat pump COP 2'3A
<br /> ❑ ❑ �]Central force�alr turnace AFUE rating,as listad in the GAMA�;�ectory,shalt be: '
<br /> 02 :78 �Options I, I!,IV,VI>VII) (�z ,88 (Option lip} �a,74(�ption V}
<br /> ❑ ❑ Qs Non-central, combustion heating systems shauhave im�rmRent ignition
<br /> ❑ ❑ �e]Maximum heatinp syslem outµul (150%of design heat load) is��STUmr. (S,5D3,2.2)
<br /> ❑ ❑ �i Hlgh efticlency torced-alr tumace (s 56,000 BTUIhr.output)may may exceed 15U%ot OHL
<br /> because: ,�GAMA listed AFUE is�. 78+ t per each 50D0 BTU/hr output that ii ezceeds the pHL.
<br /> WSEC/nsulatlon phase requlrements:
<br /> Inspected by� Date
<br /> , • � .
<br /> ❑ ❑ Q Envelope Floors shaU be insulated�Nithout compression, and with support S 24"O.C.to:
<br /> �R?9 (Options 1, II, III,IV, V) ' 0 R25(OPtions VI,Vll} ;
<br /> p p Q Non•vautted,attic Celiings shail he Insulated wflhout compressfon [o: See Table 6-2
<br /> �R-30(Options 1, II. IIi:IV, V,V!I} �R38 (OpUon VI) ��
<br /> ❑ ❑ �Door systems shall meet:Q U.40 (A l options)
<br /> Doortypesare (1�_Sreel-uvL�i.���2�5ouo �Noap_e-EUsN (3�
<br /> Page 5 oi 6
<br />
|