Laserfiche WebLink
Miss <br />Pest Report No: 15041 <br />A.A.R. TESTING LABORATORY, INC. <br />P.O. BOX 2523 Phone: (206) 881- 5812 <br />REDMOND, WA 98073 FAX: (206) 881-5441 <br />CLIENT West Coast Steel <br />ATTN Earl Bumpass <br />ADDRESS 10127 91h Ave. W. <br />Everett, WA 98204 <br />DATA <br />File. No _ "I <br />94-814 : Datea 11 3030-94_ <br />Project <br />O 8 W Glass <br />Address <br />Near 10th Q Marine View Dr <br />City <br />Everett <br />Engineer <br />N/A <br />Archtlect <br />NIA <br />ContraeMr <br />NIA <br />Owner <br />N/A <br />Permit No <br />�T--� REPORTED BATCH DATA <br />i <br />'.JOB MIX CEMENT TYPE <br />DESIGN ACTUAL <br />MIX NO' 409 <br />WEK'F�l' <br />CONCRETE :� TIME TRUCK p <br />TICKET NO R AIR <br />SLUMP <br />CONC AIR <br />CEMI LBS' <br />520 <br />GROUT 1141 053 <br />164812 <br />4112 <br />72 47 <br />I T FAGGI LBS! <br />195 3/8 <br />MOR AR <br />GA6ol LEI <br />1780 3 <br />.. OTHER <br />saNDl LBSI <br />1305 <br />FLEXBEAMS <br />�—' FASH; LBS; <br />_ <br />PRlslas� —� DESIGN STRENGTH! 3000 <br />PSI ® 2$ DAYSQ, <br />r;eN <br />GROUTEDO <br />SLUMP SPEGFICATIONI <br />4+.1 TOT CUNDS PLACED 9 <br />UNGROUTEDF—] r <br />AIRSPECIFICATION <br />PLACEMENT AREA f ;' <br />" E TRi <br />Blower room addition rigs. & slab. <br />uuLumna LJ CONFORMANCE OF WORK <br />GRADE BEAMS RE {ir't^r - i --' <br />SLABIDECK Resteel installed as per plans by �I e Eng(neeri tans n' t approved Il items Inspected Are: <br />SLAB > by city. Concrete was properly la ed & ftr'al d CONFORMING <br />PILING❑ ��I NON CONFORMING <br />OTHER^ F RE ENCE FIELD REPORT N^ 11426 ! To Approved Plans <br />CAST DATE!; 11-30- , <br />ID <br />TEST FIELD AGE <br />NO <br />__._...__I-- <br />DATE CURE (DAY <br />8730 <br />12-7 L <br />8731 <br />12 28 <br />28 <br />Copks To MAILED • ! C) 111-U' <br />(� Owner r contractor <br />r Engineer r Architect <br />r Building Dept. f Other <br />REVIEWED: <br />TEST STRENGTH <br />FRACTURE TYPE ¢t other then c :ne)' <br />;IZE <br />I AREA IWEIGHTI <br />MAX LOAD <br />STRENGTH <br />SEl <br />ON) <br />(SOIN) 1 (LBS) <br />if <br />(PSI) <br />NO <br />x12 <br />28.27 102090 <br />3610 <br />I <br />�Y12 <br />1 28.27 142880 <br />1 5050 <br />070 <br />TESTED <br />ALL REPORTS ARE CONSIDEREPFCONMEW—AL ANDMRE THE PROPERTY OF THE <br />CLIENT AND A.A.R. TESTING LABORATORY, INC. REPRODUCTION EXCEPT IN FULL, <br />WITHOUT THE WRITTEN CONSENT OF A.A.R. TESTING LABORATORY, INC. IS <br />STRICTLY FORBIDDEN. <br />