Laserfiche WebLink
CHARLES R DENNEY JUVENILE JUSTICE CENTER <br /> CODE REVIFW SUMMARY DP Proj. No.: 3-388J0/ <br /> 5.0 OCCUPANCY AND CONS7'RUCTION STANDARDS(wntinued) UBC Ref: <br /> 59 Spccial Rcquircmcnts for.[-3 Occupancy: <br /> a I ccll per 100 musl bc handicap accessiblc, H'�1C 51-?0-3/03fi <br /> b. I ccll per 20 must bc handicap acccssible 1103.L2.7(5) <br /> c. Minimum of 3%. but not Icss than onc, must be handicap accessibic and <br /> provide fon c�aring impairmcnls, FR 12.4.1 and FR 13.a.3' <br /> d. Ail troatment and esam rooms must bc handicap acccssible 1103.I.2J(G) <br /> e. Countertops at masinmm of 34-inches, It'AC 5/-20-3lOS(d)3 <br /> C 3> fi=of unenaunbcrcd spxe per occupant in eacli cell,one dimcnsion musi <br /> bc at Icast 7 fl.,iIC.4 3-JDI%-ZC-03 <br /> g. Siia(is and c�it cnc'osures �08.G <br /> h. UBC Appcndix Chaptcr"s (REVIL•fV ENTlRE�lPPEND/A) Apdx. Ch. 3 <br /> (i) Smokc stop partition per 50 inmatcs <br /> (ii) No glazing area limitations in 1-hr corridor wall <br /> (iii) Exits and door Uardw�re <br /> (iv) Fenced enclosures <br /> ' Fe�lera! Regisrcr, Vo/. .i9, No. 117, ,t4ondny, June 20. l99a. Rules nnd Rr�;ulntion.�', pg. 3170�. <br /> Regnrdirg fhe drspersiorr oj-neceasiGle ce!!s, each security�cve!mus(contnin nt lenst one, buf the mlol number oj <br /> required nccessiGle cells neerl no! be evenly dishibuted beAveen tGe vnrious securiN level:. On ce!ls jor d�e <br /> hearing iinpnimd, lhese do not nppenr to be reyuired, buf rjprovide�J, d�ev must ronjorne Nnge 3I706 nnd <br /> �I ppendrx.t 12.a.3. <br /> ThehlcGranahanPaKnershrp PaSe � <br /> The Design PaRnership,Associafe Architec(s <br /> I <br />