Laserfiche WebLink
1 OI-I44 LIFL SAFIiTI'COUG <br /> � TaLic l4$.2.1 ilarardous Area Prmec�ion la-3.a3 No�ificacion. <br /> -- 14-3.4.3.1 Oaupant Notificalion. Occupant no[ification <br /> itaxardous Arca Descrip/ion �� �Sepsntion/ProteUion .ahall be.accomp�ished.automaticallv.in accordancc with 7-63. <br /> Arcasnotincidcnlal�oresidcnlhousing 2�hr Presignal systems shall be prohihited. A positive alarm <br /> eoiler and fue4fired hwter rooms 2�hr or i-hr and sprink!ers sequence shall be permitted in accordanee with Fxteption <br /> Commcrcial cooking cquipmcnl In accordancc with 7-2.3 No.2 to 7-0.3.2. <br /> Cammissarics 1'v nr sprinklcrs <br /> Empbyce locker rooms I-hr or sprinAlers Ereepfion`: �Iny s�noAe detecfors required by(his thapter sha/f <br /> HobbyPoanJicraft shops 1-hr orsprinklors be pennrued �o be ananged ro a(arm at�a ronstantly artended <br /> Cemrai or bulk laundries over 100 sy(i locarion onfy mid sha(I nor be required m accontplish generaf <br /> (9.3 sq m) 1-hr anJ sprinAlers Q(a���� (���/(�n(ion. <br /> Maimenanccshops 1-hrorsprinklcrs <br /> Paddcdcclls Lhrandsprinkicrs 14•3A3.2 Emergency Forces Nntifitafion. Fire department <br /> Soiled iinen rooms I-hr and sprinklcrs notification shall be accomplished in accordance with 7-6.4.A <br /> Seoragc rooms > 50 sq R(4.6 sq m)in positive alarm sequcncc shall be pertnitted in acmrdance with <br /> Iarea but <10(1 sq[t(9.3 sq m)in <br /> arra smring combus�ible matcrial 1-hr orsprinklers �cepfion N0.2l0 7-63.2. <br /> Storagc rooms > ]00 sq tt(93 sq m) � �� � . . <br /> storing wmbustible matcrials 1-hr and sprinklcrs Exceptiorc: Any smoke detectors required by this d�apter s6a!! <br /> Trash coilection rooms 1-hr and sprinklcrs no!6e�equired ta trarumi!an alarm ro tlte f+re deparJmertt. <br /> 14-3.23 Where cooking facilitiCs are.prorecced in accor- 143.4.4 Detection. An approved, automatic smoke deteo- <br /> dance with 7-23,kitchens shall not be required to be provided �1100'��s[emsball be in;talled�in accx�nce wit�Secnor 7•6 .. . <br /> with roomwide protection. throughout all residcnt housing a�eas. <br /> Excep�ion No. 1: Smoke detecrors shall no� be required in <br /> 14-3J Interior Finish. :;Iceping rooms wid�f�iv or fcwcr occupants in Use Condirion 1/ <br /> 14•33.1 Interior Wall and Ceiling Finish. Inlerior wall and or 11/. ,� <br /> ceiling finish in corridors, exits, and any space not separaied F�ception No. 2: In buildings pro�eued dvoughout by an ''� <br /> (rom mrridon and exitsby a par[ition capabie ot retarding the apProved, automatic sprinkler system ir�smlfed in accordance �r� <br /> passage of smoke s}mtl be Class-A: [n slFo:he:srcas,interior - ••�'+� !4�S?,.Smokr.derertors shall not be required escept in .. �: <br /> wall and ceiling finish shall be Class A,Class B,or Class C in comdors, common spaces, and s(eeping rooms with more than <br /> accordance with Section 6-5. four occupanu. s; <br /> 14-33.21nteriorFloorFinish. Interiorfioorfinishrnaterial �CePnonNo.3: Orl�eranangementsondpositioningofsi.icke n <br /> in corridors and euits shall be Class I in accordance with Sec- derectas shal!be penniued to preven�damage or tamperin�, a� <br /> � � . .. .fnro�her.purposcr,prnvided(he fwction for detecting an��r�e is <br /> tion 6-5. Ju(fi!(ed and rhe placemcnt of detecrors is such�hat 1he speed of� � <br /> � detec�ion shal!be equivalent�o that provrded Ly the spacing and <br /> 14-3.4 Detection,Alarm,and Communications Systems. nrrangements ducnbed in Secrion 7-6. This shall be permitted to <br /> incfude �he focation of detectors in erhaus� ducts from ce(!s, <br /> 14-3.4.1 General. behind grillu, or in other lotnrioru. 7he equivalent performance <br /> o(rhe design, howwer, s6a!!be accepm6le�o die authonry hav- <br /> 143.4.1.1 Detention and correctional occupancies shall be �ng jurisdiction in accordance wirh rhe equiva(enry concepts <br /> provided with a fire alarm syslem in accordance with Section specified in Section 1-5 oJtbis Code. <br /> 7-6,except as modified by 14•3.4.1.2 through 14•3.4.4. <br /> 14-3.4.1.2 Ail required fire alartn systems shal�be electrically �4•3.5 Exlinguishment Requircments. <br /> superv•iscd. <br /> 14•3S.N High risc buildings shall comply with 14-4.3. <br /> 14-3.4.1.3 All fre alarm systems anJ dctcction systems <br /> requircd in Ihis section shall be provided with a sccondary 14-3.51 Whcrc required by 14•1.6, facilities shail be pro- <br /> �awer supply,and the installation shall be in aaordance with tected ihroughout by an approved,supervised automatic sprin� <br /> NFPA 72,Nationa!Fire Afarm Code. kler system in accordance with Section 7-7. <br /> 14-3.M1.2 Initi�tion. Initiation of the required fire alarm sys• 14-353 Whcre Ihis Code pertnits exccptions for fully sprin- <br /> tem shall be by manuai means in accordance with 7-6.2 and by klered dr.tention and cerrectional occupancies, the sprinkler <br /> means of any required detection devices or detection rystems. system shall be: <br /> L•rreptior� No. 7: Manun/�re a(nrm bauus shal!be pcm�itted to (�) In compietc acwrdance with Scction 7-7,and <br /> be(ocked,provided dmr smfrispresent wi�hin dtesubjett erea when �b) Electrically connccted to the fire alarm system,and <br /> occupied and har keys readily available�o unlock�he fwses. <br /> / Erteprion Na. 2: Manual fre a(ann bozes shaU bc permirred m (c) Fully superviscd. <br /> Le located in a sm��loca(ion,.prevuled,dm� die c(aJ�ln:a�inn is <br />. nrrendeJ when the building is occupied and that d�e smf/'nuen• 14•3.5.4 Portable fire extinguishers shall be provided in <br /> dant h.as dirtet supervisron o/'die slccping orca. accordancc with 7-7.4.1. <br /> YYN EDIiION <br />