Laserfiche WebLink
1Vithcrs <br /> Plan Check No. C0407-0?-1 <br />� August 33, 2004 <br /> Paae 2 of 2 <br /> 1 1. Verify minimum 3G' landing at top and bottom of stairs (longer Iread minimum). <br /> 12. Provide detail oC thermal break betwecn the house and�arage. <br /> l3. Shcw iigid ins� 'ion on floorplan (R-10 minimum). <br /> 14. Show attic ventilation calculations. Spe�ify size :md location of all vents. <br /> 15. Provide continuous rim joist where joists under braced wall panels nre cantilevered. <br /> Specify connection rcyuiremen[s per Section R301.2.2.2.2, Exception #4. <br /> 16. Provide Washingron State Energy Code requirements and notes on drawings. <br /> 17. Provide Vl'ashington State ventilation and indoor air quality notcs and requiremcnts on <br /> drawings. _ <br /> 18. Specify nailing per table R6023(l) IRC. <br /> 19. Provide general notes for minimum desi_n cn�eua, indudin� but not limited to Roof Load, <br /> Floor Load, Esterior Decks Lcr.id, Soil Beanna �assumed), Concrete Str�ngth, ReinCorcing <br /> Steel Grade, Praming Species �nd Grade, Joist & Rafters, Headers, etc... <br /> Please preparc a response letter showin� where each item in this correction letter is addressed on .he plan <br /> set. <br /> Upon resubmittal of the dra�vin��s, yow� application ���ill be given prioriry and plan review will <br /> recommencc. <br /> All required submittals shall be o( su(�icicnt detail and contain sufficien[ inPomiation to ensure that the <br /> proposed stmcture will be consuvcted in compliance �a�ith all adopted codes. <br /> Sincerely, <br />� J/( �1+.�---- <br /> Jeff Heilman <br /> Development "Cechnician <br /> S:ULindsar\1VOItDUiGILA7A\.J\Plan chcck\u COJ07-02d.doc <br /> Z� <br />