< < <br /> PUBL/C N/O/�I�LS' <br /> November1, 2001 <br /> lames Thomas <br /> Architr,cmral Design <br /> 2221 I�verett Avenue <br /> Suite N203 <br /> Everett, WA 98201 <br /> RE: Owner: Just Rite Construction <br /> Job Address: 8224 - 5'" Avenue W. <br /> Plan Check No: BO110-043 <br /> Dear Mr. Thomas: <br /> In response to your application for a construction permit, your plans have been examined and you are advised <br /> that the issuance of a permit is being withheld for the reasons listed below. These comments address building <br /> issues only, additional revisions or additions may be required by other departments (such as Utilities, Planning <br /> or Fire). All references refer ro the 1997 Uniform Building Code, as amended by the State of Washington <br /> and/or Washington State Energy Code 2001 Edition, unless staced od�erwise. <br /> In order for the processing of your application to continae, it will be necessary to provide the Building <br /> Division with two complete new sets of drawings reflecting the cnrrections requested. , <br /> I. A one-hour fire-resistive uccupancy separation is required between the garages and the apartments per <br /> UBC 302.1 & 302.4. This would include one-hour walls, one-hour doors, one-hour floor-ceiling <br /> assemblies, and the walls that support the floor-ceiling assemblies (UBC 302.2) Provide the justifying <br /> testing agency identification numbers and descriptions. <br /> 2. Provide dimensions on the elevations to verify that the garage level qualifies as a basement. See I <br /> definition of "Basement" and "Story" in Chapter 2. � <br /> I <br /> 3. Provide structural calculations for [he retaining wall shown in the typical wall sectioa � <br /> 4. Provide fire blocking for [he typical party wall section at the foors and attic junctions per UBC 708.1 & � <br /> 2. � <br /> Please prepare a response letter showing where each item in this correction letter is addressed on the plan set. � <br /> Upon resubmittal of[he drawings, your application will be given priority and plan review will recommence. <br /> �:II required submittals shall be of sufficient detail and contain sufficient information ro ensure that the proposed <br /> s[rucnue will be constructed in compliance wi[h all adopted codes. <br /> Sincerely, (y��� <br /> � � �� <br /> Steve Miller <br /> Associate Engineer <br /> DEDGPUCA�ISTR:UILL[R�Ln110uU�SI_J STiI TVE 0.'I <br /> CITY OF EVERETT• 3200 Cedar Sireet • Everetl. WA 98201 • (425) 257-6800 • Fax (425) 257-8856 I <br />