8327 5TH AVE W 2016-01-01 MF Import
>
Address Records
>
5TH AVE W
>
8327
>
8327 5TH AVE W 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/3/2017 10:11:04 AM
Creation date
4/3/2017 10:10:32 AM
Metadata
Fields
Template:
Address Document
Street Name
5TH AVE W
Street Number
8327
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
161
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
..('RUCTURAL DESIGN ASSV.;IATES, INC. <br /> , � CONSULTING ENGINEERS <br /> sex � ieerM sr. sw. • a.o. eox sxs <br /> LYNNWOO�, WA 8BOJ6 . PMONE. �XY� ]IS)q� <br /> December 27, 1983 <br /> Lnyeari Construction <br /> ATTN: Ken Enyeart <br /> 10214 Marine View Drive <br /> Everett, \VA 98204 <br /> Subject: Apartmeni Building at 8327 Hardeson Road <br /> Everett, WA <br /> Dear Ken: <br /> In accordance with your request on December 27, 1983, an inspection <br /> was made on the above referenced apartment building. The building <br /> is partially completed (approximately 60%). Overall, the building is <br /> in good condition and structurally there is no major repair or replace- <br /> ment necessary. <br /> However, the following items should be accomplished prior to any <br /> new work: <br /> I. Replace all exterior gypsum wall board. <br /> 2. All of the wet floor plywood shall be replaced. � <br /> � <br /> r: <br /> 3. Replace broken and or missing wall studs. <br /> c� <br /> 4. Pump out water in the south end of the basement <br /> and check foundation und column connectionv. <br /> H � <br /> 5. All of the cantilevered balcony Trus 7oist members y ' <br /> (TJI's) that have plywood nailed to their sides shall c~i� � <br /> be re-nailed. <br /> 6. The electrical wiring had been cut and damaged and � � <br /> it is recommended tha? all the wiring be replaced. � F. <br /> if you have any questions, please give us a call. � � <br /> � ` <br /> Very truly yours, � : <br /> H � <br /> STRI� T RAL ESIGN ASSOCIATES, INC. � `" <br /> by: , i /11 p �. <br /> /t, ,� : <br /> , � �; �-,�.� <br /> , , � �;� <br /> � � �� <br /> I�ase Vanden Ende, P.E. r: <br /> President � � <br /> y ti <br /> . �. <br /> � i.,. .. . � r:nlNthklr�(: C�C�.I;.ri '.I.G .�J� � � i ._ . . , r- <br /> . . . � . , _ • . �.iN!iAiit�y� • VI. � ..��,"lt�, �V:.i i ' • �� .. .. . � . . r � . .. <br />