. <br /> . � . <br /> ____________________________�==___=_____=_________=____===_=__________=_=_______ <br /> WATTSUN 5.6 COMPOI�fENT CHECKLIST 04/08/99 <br /> FILE: C:\\WATTSUN5\\BROKAW.WS HOUSE ID: <br /> Name: Nan�y Brokaw Floor Area: 500 ft2 <br /> Address: Heating Type: Electric: Zoned <br /> Reference: 1997 WA State Energy Code <br /> -------------------------------------------------------------------------------- <br /> FRAMING INSPECTION <br /> --------------------------------------------------------------------------- <br /> Approved plans: <br /> Are available onsite ', <br /> Wall framing: I <br /> Net wall area: 268 ft2 <br /> Intermediate framing with studs spaced 16" o.c. , H10 insulated <br /> headers and no isolated cavities which cannot be insulated. <br /> Structural panels: <br /> All structural sheathing is stamped "Exposure I" or "Exterior" . <br /> Windows: <br /> (Milgard Horiz. Sldr. 51'l0 AR/LE 21 . 5 ft2) <br /> (M.ttgard Pic. 5320 AR/LE 15.0 ft2) <br /> (Milgard Vinyl If5220 AR/LE 7 . 5 ft2) <br /> Windows are installed as shown on the approved plans. The rough <br /> opening around windows and doors is caulked/sealed. <br /> Exhaust fans, spot ventilatiun: <br /> Bathroom f'ans are Home Ventilating Institute-rated 50 CFM <br /> ^ (minimum) . <br /> Kitchen fans are HVI-rated 100 CFM (minimum) . <br /> _ Fan ducting has minimal bends and terminates outside <br /> of the building. <br /> The whole house ventilation fan supplies between BO and 120 CFM. <br /> Exhaust fans, whole house ventilation: <br /> The designated whole house fan is is rated at 1 . 5 sones or less <br /> (unless remotely locatedl . <br /> INSULATION INSPECTION <br /> --------------------------------------------------------------------------- <br /> Wall insulation: <br /> (R19 INT Lap Wood 268. 0 f't2 ) <br /> Insulation fills all exterior wall cavities . It is not compressed <br /> and is cut to fit around wires, pipes , and outlet boxes. Reces�ed <br /> fixtures in exterior walls have at least R-5 insulation behind <br /> them. . <br /> __ Vapor Retarder: <br /> 1 .0 perm or less vapor retarder (e.g. poly, kraft paper, <br /> perm rated paint) is installed on the warm side of insulation <br /> - Page 1 ___________________________________ <br />