<br /> INSPECTION �MPORTANT:Suppiy Inforcnatlon and check approprlate circles !n the shaded boxes.
<br /> APPROVED Disregard topics that don't describe your bulldinA or equlpment.�D.d.QI place checks In
<br /> the two left columns.
<br /> �i� � '��� ���
<br /> _ __. . ____ _.____._.
<br /> :� O 14 Prescrlptive exhaust ventllallon exhaust req�irements for each dwelling unft (VIAQ, S.303): �':
<br /> . , ,��:.� �., ., .-:, <,:. .. .,<:.: � .4 ,v�,� .m,.: ,,. -,.,,. �r� �;��;
<br /> Mlnimum(.25 w.g.) MfrJmodel V Fan Iabcl .1WG) �'��"
<br /> , �,•_ .: ( �
<br /> ' Kilchenfan SU0�90'CFM '� nJ 25 �O '3 � �`
<br /> rt:s:�3
<br /> x�.>,»
<br /> i' Bathroom fan( ) 50 CFM �.:
<br /> �;�:
<br /> ; Bathroom tan( ) 50 CFM • _�';
<br /> ;: C�athroom fan( ) 50 CFM �'�
<br /> �F52<i:
<br /> ; Laundry fan 50 CFM ;<'`
<br /> 50 CFM (1-2 bedrms) .
<br /> 75 ' � ' ' 80 CFM (3 bedrms) ry `
<br /> .. • • .
<br /> 100 CFM (4 bedrms)
<br /> WFiole"house'ft+n: Locatlon,�;�a'x'a-+`� Soneratinq """�_ (c1.5:ifatticfan'closer}hanb'to
<br /> ce!l1n9J. ' ; ,
<br /> � Whoie house fan is ifStedllabled"for Goniinuous use". '
<br /> Q Whole fiouse fan wiring for control routed to cent:�al bcation (rlehum�dlstatonlyj
<br /> O � �s Whola house fan also serves as a kitchen ar bath spat fan: �j Yes ; (� No '
<br /> (spot fan de5ignated as a whote house fan shali meet;whote house-fan requlrements:�
<br /> O O » Spot tan isn't'suftable for Whole house tan and must be seperate QYes �•No � ••
<br /> O O 1e 1Nhole house fan shail run continuously: Kitchen(25C�hA), Bath 8�laundry(2oC�Mj{�Yas Q,No
<br /> O O 19 Integ�ated forced-alrtumace ventllation(see loomote)(VlAQ Gode,S:3U3.y_2{bJ}shaq be
<br /> - synchronized with a wnole house fan fo sGpply tresh air to the tiwelling: ;Q Yes ' N� '
<br /> Q U yes,a s"diameteroutside air inlet duct w/ motorized damper shaU ivn trom th�u�ding'
<br /> exterior to ihe furnaoe return plenum and 3imit tlie ventiltion rate to betweeri.35'r:5 ACH,
<br /> Q Moditications to the abave integrated`7orced air system may require pedorrnance testtag;j tria
<br /> manner acceptabla to tbe buikling oHicial, to demonsirate':.35 -,5 Alr ChangesMnur. .
<br /> 'Five bedrooms or iarger requires a desi�ned whole house fan system {Rate �s,35-.5;ACH).
<br /> � p Q Mechanlcal ventliatlon fan ducts shall be z 4�and properly sized (VIAQ, Table 3-3).
<br /> � � � � • �
<br /> O O Q Fresh air shall be provlded tor.each dwehing unft as follows;(UTAQ,S.302.6.1}; '.
<br /> ach bedroom:Tasted, screened, controllabie, through-wail port (z 4 Sq,'ln,}to i�e exterioi.
<br /> nr� ach recreatlon room;One wall port ae specifie8 for bedrooms. ; .,
<br /> , -.: � ;
<br /> Y, ther enclosed "habltabie".rooms: One wall poii as speci�ied for kedrooms, :
<br /> verall'iiviqg area:One wall port as specitied(o(bedrooms.
<br /> C7 O QOR �IntegFated forcetl air fuCnace which delivers outside makeup aiYthrough the'.ducHh�system
<br /> WSEC Framing phase requirements:
<br /> Inspected by Date page 6