Laserfiche WebLink
I S T R U C T U R A L N O T E S <br />1.0 GENERAL <br />THESE STRUCTURAL NOTES SUPPLEMENT THE SPECIFICATIONS, <br />ANY DISCREPANCY FOUND AMONG THE DRAWINGS, <br />SPECIFICATONS, THESE NOTES, AND THE SITE CONDITIONS <br />SHALL BE REPORTED TO THE ARCHITECT, WHO SHALL CORRECT <br />SUCH DISCREPANCY IN WRITING. ANY WORK DONE BY THE <br />CONTRACTOR AFTER DISCOVERY OF SUCH DISCREPANCY SHALL. BE <br />DONE AT THE CONTRACTOR'S RISK. THE CONTRACTOR SHALL <br />VERIFY AND COORDINATE THE DIMENSIONS AMONG ALL DRAWINGS <br />PRIOR TO PROCEEDING WITH ANY WORK OR FABRICATION. THE <br />CONTRACTOR, iS RESPONSIBLE FOR ALL BRACING AND SHORING <br />DURING CONSTRUCTION. <br />1.1 CODES <br />ALL METHODS, MATERIALS AND WORKMANSHIP SHALL CONFORM TO <br />THE REQUIREMENTS OF THE CITY OF EVERETT AND: THE 1994 <br />UNIFORM BUILDING CODE (UBC), AS AMENDED AND ADOPTED BY <br />THE CITY OF EVERETT AND THE STATE OF WASHINGTON; <br />A.C.I. 318-89 (REVISED 1992); A.I.S.C. 9TH EDITION; <br />AWS; A.I.T.C. 2ND EDITION; AND A.I.S.I 1986 EDITION AND <br />1989 ADDENDUM. <br />1.2 DESIGN CRITERIA <br />A. VERTICAL LOADS <br />1. LIVE LOADS <br />ROOF (SNOW) 25 PSF <br />FLOORS (RESIDENTIAL) 40 PSF <br />DECKS (RESIDENTIAL) 40 PSF <br />EXIT FACILITIES 100 PSF <br />NOTE: SPECIAL SNOW LOADS AT LOWER ROOFS UNDER ROOF ABOVE <br />SHALL BE CALCULATED PER UBC APPENDIX CHAPTER 16, SECTION <br />1641 PER BUILDING OFFICIAL'S REQUIREMENT. ADDITIONAL SNOW <br />LOADS WILL BE APPLIED TO THE AMOUNT LISTED ABOVE. <br />B. LATERAL LOADS: <br />ALLOW 33-1/3% INCREASE IN STRESSES FOR WIND AND <br />SEISMIC FORCES. LATERAL FORCES ARE TRANSMITTED BY <br />DIAPHRAGM ACTION OF THE FLOORS TO SHEAR WALLS. <br />LOADS ARE THEN TRANSFERRED TO THE FOOTINGS, WHERE <br />ULTIMATE DISPLACEMENT IS RESISTED BY PASSIVE <br />PRESSURE OF EARTH AND SLIDING FRICTION OF EARTH. <br />OVERTURNING IS RESISTED BY THE DEAD LOAD OF THE <br />STRUCTURE. <br />1. WIND: EXPOSURE B, BASIC WIND SPEED = 80 <br />M.P.H., PER UPC <br />2. SEISMIC - ZONE 3 PER UBC <br />Z*I*C*W/Rw - Z=0.3 1=1.0 C=2.75 Rw=6.00 <br />V=0.1375*W <br />(W = DEAD LOAD OF STRUCTURE) <br />1.3 SOIL DATA (PER GEOTECHNICAL REPORT # 1374897 DATED <br />2/14/97 PREPARED BY NELSON - COUVRETTE do ASSOC., INC.) <br />FOR LOCATIONS SEE SOILS REPORT. SOIL BEARING @ CONT. <br />SPREAD FOOTINGS = 2500 PSF. ACT <br />IVE AND PASSIVE PRESSURES <br />ARE 35 PSF AND 250 PSF RESPECTIVELY. WHERE GEOTECHNICAL <br />REPORT HAS NOT BEEN PROVIDED, THE ABOVE VALUES ARE <br />ASSUMED AND THESE VALUES SHALL BE FIELD VERIFIED. <br />1.4 SHOP DRAWINGS <br />SUBMIT SUFFICIENT COPIES OF SHOP DRAWINGS TO <br />ARCHITECT/ENGINEER FOR THE FOLLOWING: <br />1. CONCRETE MIX DESIGNS <br />2. P.E. FLOOR JOISTS <br />3. P.E. ROOF/FLOOR TRUSSES <br />DO NOT FABRICATE PRIOR TO ARCHITECT'S/ENGINEER'S <br />APPROVAL. <br />2.0 SITE WORK <br />2.1 EXCAVATION - (PER GEOTECHNICAL REPORT If 1374897 DATED <br />2/14/97 PREPARED BY NELSON - COUVRETTE & ASSOC., INC.) <br />EXCAVATE FOR FOOTINGS DOWN TO DEPTH SHOWN ON DRAWINGS OR <br />TO FIRM UNDISTURBED MATERIAL. AREAS OVER -EXCAVATED SHALL <br />BE BACKFILLED WITH LEAN CONCRETE (f'c = 2000 PSI), OR <br />BE STRUCTURALLY FILLED PER SECTION 2.2 AND SHALL BE AT <br />THE CONTRACTOR'S EXPENSE. <br />2.2 BACKFILL AND COMPACTION - (PER GEOTECHNICAL REPORT f <br />1374897 DATED 2/14/97 PREPARED BY NELSON - COUVRETTE <br />do ASSOC., INC.) <br />BACKFILL SHALL NOT BE PLACED UNTIL AFTER THE REMOVAL OF <br />ALL FORMS, SCREEDS, OTHER WOOD DEBRIS AND MATERIAL <br />SUBJECT TO ROT OR CORROSION. USE ONLY MATERIALS <br />APPROVED FOR BACKFILL. IN AREAS UNDER SLABS OR FOOTINGS, <br />MATERIAL SHOULD BE PER SOILS REPORT, PLACED IN 8" MIN OR <br />10" MAX LIFTS AND COMPACTED TO AT LEAST 90-92% OF MAXIMUM <br />DRY DENSITY AS DETERMINED BY ASTM D 1557 TEST. THE FILL <br />SHOULD BE CLEA", GRANULAR MATERIAL. ANY NATIVE SOILS <br />ON SITE USED AS FILL MUST MEET LIMITATIONS LISTED IN SOILS <br />REPORT. <br />3.0 CONCRETE <br />3.1 GENERAL <br />NORMAL WEIGHT CONCRETE MEETING THE REQUIREMENTS OF ACI <br />301-89 ESTABLISH PROPORTIONS OF CEMENT, COURSE AND FINE <br />AGGREGATES, WATER, AND ADMIXTURES TO PRODUCE THE <br />PROPERTIES SPECIFIED FOR EACH CONCRETE MIX TYPE PER ACI- <br />301 ON THE BASIS OF PREVIOUS FIELD EXPERIENCE OR TRIAL <br />BATCHES. USE ADMIXTURES IN ACCORDANCE WITH THE <br />MANUFACTURER'S DIRECTIONS. USE AMOUNTS OF WATER - <br />REDUCING ADMIXTURE THAT WILL PERMIT PLACING WITHOUT <br />SEGREGATION, HONEYCOMBING OR ROCK POCKETS. THE SLUMPS <br />SPECIFIED ARE THE SLUMPS REQUIRED AT THE POINT OF <br />PLACEMENT INTO THE STRUCTURE. USE INTERIOR MECHANICAL <br />VIBRATORS WITH 7000 RPM MINIMUM FREQUENCY. DO NOT OVER - <br />VIBRATE. CONCRETE SHALL BE POURED MONOLITHICALLY <br />BETWEEN CONSTRUCTION OR CONTROL JOINTS. PROTECT ALL <br />FRESHLY PLACED CONCRETE FROM PREMATURE DRYING AND <br />EXCESSIVE HOT OR COLD TEMPERATURES FOR SEVEN DAYS AFTER <br />POURING. PROVIDE ENGINEER WITH PROPOSED CONSTRUCTION OR <br />CONTROL JOINT LOCATIONS FOR HIS APPROVAL, OR USE JOINTS <br />AS SHOWN ON THE DRAWINGS. ALL REINFORCEMENT TIE WIRES <br />AND FORM ANCHORS SHALL BE CUT OFF FLUSH WITH THE <br />SURFACE; SURFACES WHERE EXPOSED SHALL BE SMOOTH AND <br />FREE FROM IRREGULARITIES. CONDUITS & PIPES EMBEDDED <br />WITHIN THE SLAB (OTHER THAN THOSE MERELY PASSING <br />THROUGH) SHALL SATISFY THE FOLLOWING: <br />1. THEY SHALL BE NOT LARGER THAN ONE THIRD THE <br />OVERALL THICKNESS OF THE SLAB IN WHICH THEY <br />ARE EMBEDDED. <br />2. THEY SHALL BE SPACED NOT CLOSER THAN THREE <br />DIAMETERS OR WIDTHS ON CENTER. AT ELECTRICAL <br />ROOMS OR CONGESTED AREAS WHERE MINIMUM SPACING <br />CANNOT BE ACHIEVED, USE #6 AT 12" O.C. EACH <br />WAY EXTENDING A MINIMUM OF TWO FEET BEYOND <br />CONGESTION. MORE THAN ONE LAYER OF CONDUIT IS <br />NOT PERMITTED UNLESS APPROVED BY THE ENGINEER. <br />3. THEY SHALL NOT IMPAIR SIGNIFICANTLY THE <br />STRENGTH OF CONSTRUCTION. <br />4. THEY ARE NOT EXPOSED TO RUSTING OR OTHER <br />DETERIORATION. <br />5. THEY ARE OF UNCOATED OR GALVANIZED IRON OR <br />STEEL NOT THINNER THAN STANDARD SCHEDULE 40 <br />STEEL PIPE. <br />3.2 STRENGTH <br />DESIGN MIXES TO PROVIDE NORMAL WEIGHT CONCRETE WITH THE <br />FOLLOWING PROPERTIES: <br />F'c <br />PSI <br />WATER/CEMENT <br />RATIO <br />SLUMP <br />INCHES <br />AIR <br />ENTRAINMENT <br />FOOTINGS <br />2500 <br />0.50 <br />5 <br />0.0% <br />FOUNDATION WALLS <br />2500 <br />0.50 <br />5 <br />0.0% <br />SLABS ON GRADE <br />2500 <br />0.50 <br />5 <br />0.0% <br />(INTERIOR) <br />SLABS ON GRADE <br />2500 <br />0.48 <br />5 <br />5.0% <br />SUBNOTES: <br />1. ANY OF THE ABOVE MIXES CAN BE USED FLOWABLE <br />(8" TO 11" SLUMP) IF THE PROPER ADD!TION OF <br />ADMIXTURES IS INCLUDED AND THE W/C RATIO IS <br />NOT INCREASED. <br />2. AT OWNERS OPTION, SLABS ON GRADE MAY CONTAIN <br />WELDED -WIRE OR FIBER -MESH. EITHER ONE OF THESE <br />MAY BE USED TO ASSIST IN THE PREVENTION OF <br />VARIABLE SHRINKAGE AND CRACKING. <br />3. THE PROPORTIONS APPROVED SHALL BE CAREFULLY <br />MAINTAINED. NO DEVIATION FROM THESE <br />PROPORTIONS, ESPECIALLY THE ADDITION OF WATER, <br />SHALL BE MADE WITHOUT APPROVAL OF THE <br />ENGINEER. <br />3.3 MATERIAL - CEMENT, WATER do AGGREGATES PER ACI 301 <br />A. CEMENT MUST CONFORM TO ASTM 150, TYPE I OR TYPE II. <br />ENGINEER'S APPROVAL IS REQUIRED FOR USE OF TYPE III <br />CEMENT. <br />B. WATER TO BE CLEAN AND POTABLE. <br />C. COARSE AND FINE AGGREGATES TO CONFORM TO ASTM-C33. <br />3.4 MATERIALS <br />A. WATER REDUCING ADMIXTURES: CONCRETE USING POZZOLITH <br />ADMIXTURES TO PRODUCE FLOWABLE CONCRETE MAY BE <br />USED WITH THE ENGINEER'S APPROVAL AND MUST CONFORM <br />TO ASTM-C494, POZZOLITH POLYHEED, POZZOLITH 10OXR, <br />OR POZZUTECH 20. POZZOLITH SHALL BE INCORPORATED <br />INTO ALL CONCRETE IN EXACT ACCORDANCE WITH THE <br />MANUFACTURER'S INSTRUCTIONS. ADMIXTURES AND <br />DOSAGES WILL VARY DEPENDING ON CLIMATIC CONDITIONS <br />AND THE CONTRACTOR'S JOBSITE REQUIREMENTS. MAXIMUM <br />SLUMP FOR SUCH CONCRETE SHALL NOT EXCEED 8" WITH A <br />MINIMUM OF 10 OUNCES OF POLYHEED PER 100 OUNCES OF <br />CEMENT. GREATER SLUMP MAY BE ACHIEVED UP TO 11", WITH <br />CORRESPONDING AMOUNTS OF ADMIXTURE. IN ACCORDANCE <br />WITH MANUFACTURER'S RECOMMENDATIONS. <br />B. .AIR ENTRAINMENT: CONFORM TO ASTM-C260 AND ASTM- <br />C494, MBVR OR MICRO -AIR BY MASTER BUILDER. ENTRAIN <br />5% +/- 1% AIR BY VOLUME IN ALL EXPOSED CONCRETE. <br />C. OTHER ADMIXTURE: NO OTHER ADMIXTURES PERMITTED <br />UNLESS PRIOR APPROVAL IS GIVEN BY THE ENGINEER. <br />3.5 REINFORCING STEEL <br />DETAIL, FABRICATE AND PLACE PER ACI-315 AND ACI-318. <br />SUPPORT REINFORCEMENT WITH APPROVED CHAIRS, SPACERS, OR <br />TIES. <br />A. STEEL REINFORCEMENT SHALL BE NEW, DEFORMED BILLET <br />STEEL, MEETING ASTM STANDARD "A" 615-93; GRADE 60 <br />FOUR #3 AND LARGER BARS UNLESS NOTED OTHERWISE ON <br />THE PLANS. SHOP DRAWINGS SHALL BE MARKED <br />ACCORDINGLY AND SUBMITTED TO THE ENGINEER FOR <br />REVIEW PRIOR TO FABRICATION. GRADE 60 REBARS SHALL <br />NOT BE BENT IN FIELD AFTER CONCRETE PLACEMENT. ALL <br />BEND SHALL BE PER ACI. <br />B. REINFORCEMENT IN ALL WALLS, SLABS, AND FOOTINGS <br />SHALL BE CONTINUOUS AROUND CORNERS OR CORNER BARS <br />PROVIDED, BOTH VERTICAL AND HORIZONTAL. <br />C. LAPS: ALL TENSION SPLICES ARE ACCORDING TO ACI 318, <br />CLASS B AND ALL COMPRESSION SPLICES ARE 30 <br />DIAMETERS FOR Vc GREATER THAN 3000 PSI AND ARE 40 <br />DIAMETERS FOR f'c WHICH IS LESS THAN 3000 PSI, <br />UNLESS NOTED OTHERWISE. <br />D. TRIM REINFORCING: AROUND ALL OPENINGS SHALL BE A <br />MINIMUM 1-#5 TOP AND BOTTOM, EXTENDING 2'-6" BEYOND <br />OPENING AT EACH CORNER. SEE TYPICAL DETAILS. <br />E. WELDING: TACK WELDING OF REBAR IS NOT PERMITTED <br />UNLESS CALLED FOR AND APPROVED BY THE ENGINEER. <br />F. MINIMUM REINFORCING: WHERE REINFORCEMENT IS NOT <br />SHOWN ON THE DRAWINGS, THE "BUILDING CODE <br />REQUIREMENTS FOR REINFORCED CONCRETE"(ACI 318) <br />SHALL BE REFERRED TO FOR PROPER REINFORCEMENT. <br />G. REBAR COVER: PROVIDE CONCRETE PROTECTION FOR <br />REINFORCEMENT AS FOLLOWS: <br />2" CONCRETE DEPOSITED AGAINST FORMS BUT <br />EXPOSED TO EARTH <br />1-1/2" MAIN REINFORCING IN BEAMS <br />1-1/2" TO TIES IN COLUMNS, AND TIED REBAR IN WALLS <br />1-1/2" FOR BARS IN SLABS ON GROUND <br />1" FOR BARS IN SLABS ON FORMS <br />H. WELDED WIRE FABRIC: ASTM-A185 AND ASTM-A82 <br />I. DEFORMED BAR ANCHORS: ASTM-A496 <br />K. FIBERMESH: PROVIDE FIBERMESH STRANDS WITHIN <br />CONCRETE PER THE MANUFACTURERS SPECIFICATION IF <br />FIBER MESH USED WITHIN SLABS ON GRADE. <br />3.6 EPDXY DOWELED REINFORCEMENT <br />A. ALL REINFORCEMENT 'WHICH IS TO BE DOWELED INTO EXISTING <br />CONCRETE SHALL BE INSTALLED WITH RAWL "POWER -FAST" EPDXY <br />ADHESIVE PER ICBO REPORT #4514 OR APPROVED EQUAL. <br />B. EPDXY SHALL BE MIXED, APPLIED, AND CURED IN ACCORDANCE WITH <br />THE MANUFACTURERS GUIDELINES. REINFORCEMENT AND CONCRETE SHALL <br />BE CLEAN AND FREE OF IRREGULARITY. EPDXY SHALL NOT BE MIXED OR <br />CURED IN AIR AND / OR CONCRETE TEMPERATURES BELOW 50 DEGREES <br />FAHRENHEIT. <br />C. EPDXY DOWELING OF REINFORCEMENT IN OVERHEAD APPLICATIONS <br />SHALL NOT BE ALLOWED WITHOUT PRIOR WRITTEN APPROVAL FROM THE <br />ENGINEER OF RECORD. <br />3.7 INSPECTIONS <br />CONCRETE INSPECTIONS SHALL BE FOLLOWED PER THE 1994 UBC <br />SECTIONS 1701 AND 1702 AND/OR AS REQUIRED BY THE LOCAL <br />BUILDING DEPARTMENT. THEY SHALL BE DONE BY AN <br />INDEPENDENT AGENCY EMPLOYED BY THE OWNER,. JOBSITE <br />VISITS BY THE ENGINEER DO N01 CONSTITUTE AN OFFICIAL <br />VISIT. <br />3.8 SERVICEABILITY <br />SPECIAL NOTE: CONCRETE IS NOT A MAINTENANCE FREE <br />MATERIAL. CRACKS CAN BE EXPECTED TO OPEN UP WITHIN 2 <br />YEARS OF CONSTRUCTION AND SHOULD BE FILLED AT THIS POINT <br />AND AS REQUIRED THEREAFTER. <br />4.0 CARPENTRY <br />4.1 ROUGH CARPENTRY <br />ALL 2x FRAMING LUMBER SHALL BE STUD GRADE HEM -FIR OR <br />STUD GRADE DOUG FIR FOR STUDS AND STANDARD FOR PLATES <br />OR AS SHOWN ON THE DRAWINGS OR BELOW. ALL 2" LUMBER <br />SHALL BE KILN DRIED (KD) OR SURFACE DRIED (SD). UNLESS <br />NOTED OTHERWISE. AS GREEN DOUG FIR MATERIAL WILL BE USE <br />THE OWNER MUST REALIZE PROPENSITY FOR SHRINKAGE IS HIGHER <br />AND THIS MAY IMPACT STRUCTURE MORE THAN USING KID OR SD <br />MATERIAL. EACH PIECE OF LUMBER SHALL BEAR THE STAMP <br />OF THE WEST COAST LUMBER INSPECTION BUREAU (WCLIB) <br />OR WESTERN WOOD PRODUCTS ASSOCIATION (WWPA) SHOWING <br />GRADE MARK OR APPROVED EQUAL. <br />BASEMENT LEVEL BEARING WALLS ® (3) THREE FLOOR UNITS <br />THAT ARE PARTY WALLS SHALL BE 2x4 © 12" O.C. UNLESS <br />NOTED OTHERWISE. ALL OTHER INTERIOR BEARING WALLS SHALL <br />BE 3x4 ® 16" 0.1 SPACING. USE 2x6 @ 16" O.C. FOR ALL <br />BEARING WALLS SHOWN AS 2x6 CONSTRUCTION. <br />MEMBER <br />SPECIES <br />2x <br />& 3x STUDS <br />STUD GRADE HEM -FIR <br />2x <br />JOISTS <br />#2 <br />HEM -FIR <br />4x <br />HEADERS <br />#2 <br />HEM -FIR <br />4x <br />COLUMNS <br />#1 <br />HEM -FIR <br />6x <br />HEADERS <br />#2 <br />DOUG-FIR <br />6x <br />COLUMNS 1#1 <br />HEM -FIR <br />FINGER JOINTED STUDS W/ EXTERIOR GLUE MAY BE USED <br />ONLY WITH WRITTEN APPROVAL OF THE ENGINEER OF RECORD. <br />ALL EXPOSED MATERIALS OR MATERIAL IN CONTACT WITH <br />CONCRETE SHALL BE PRESSURE TREATED (SEE SECTION 4.10). <br />4.2 TJI/TJL JOISTS (SEE PARAGRAPH 5.3 FOR NOTES ON ALTERNATE <br />JOISTS AND FOR DEFLECTION CRITERIA FOR P.E. ROOF AND <br />FLOOR TRUSSES AND FLOOR JOISTS) <br />A. FABRICATION: <br />THE TRUSS MANUFACTURER SHALL VERIFY ALL SETBACKS <br />AND DIMENSIONS PRIOR TO FABRICATION. ALTERATION OF <br />THE TRUSS LAYOUT INDICATED ON THE PLANS MAY REQUIRE <br />SUPPORTING STRUCTURAL AND FOUNDATION CHANGES. <br />THEREFORE PRIOR APPROVAL BY THE ARCHITECT AND <br />STRUCTURAL ENGINEER IS REQUIRED. WHERE THE VENDOR <br />REQUIRES 2 SPAN CONTINUOUS FRAMING TO HAVE THE TOP <br />CHORD CUT AT THE INTERMEDIATE SUPPORT THE ENGINEER <br />SHALL BE NOTIFIED. MAXIMUM ALLOWABLE TOTAL LOAD <br />DEFLECTION SHALL BE SPAN/240 UNLESS NOTED <br />OTHERWISE. <br />B. STORAGE AND HANDLING: <br />THE TJI JOIST IF STORED PRIOR TO ERECTION, SHALL BE <br />STORED IN A VERTICAL POSITION AND PROTECTED FROM <br />THE WEATHER. THEY SHALL BE HANDLED WITH CARE SO <br />THEY ARE NOT DAMAGED. <br />C. ERECTION AND INSTALLATION: <br />THE TJI JOISTS ARE TO BE ERECTED AND INSTALLED IN <br />ACCORDANCE WITH THE PLANS AND WITH THE <br />RECOMMENDATIONS IN THE MANUFACTURER'S MANUAL. <br />TEMPORARY CONSTRUCTION LOADS WHICH CAUSE STRESSES <br />BEYOND DESIGN LIMITS ARE NOT PERMITTED. ERECTION <br />BRACING, IN ADDITION TO THAT SPECIFIED IS TO BE <br />PROVIDED TO KEEP THE TJI JOISTS STRAIGHT AND PLUMB <br />AS REQUIRED AND TO ASSURE ADEQUATE LATERAL SUPPORT <br />FOR THE INDIVIDUAL TJI JOISTS AND THE ENTIRE <br />SYSTEM, UNTIL THE SHEATHING MATERIAL HAS BEEN <br />APPLIED. SEE THE MANUFACTURERS MANUAL FOR <br />ADDITIONAL_ NOTES REGARDING ERECTION BRACING FOR <br />OPEN WEB SERIES JOISTS. <br />TRUS JOIST CLEAR SPANS BEYOND 70 FEET ARE TO BE <br />ERECTED IN ACCORDANCE WITH MANUFACTURER'S <br />RECOMMENDATIONS WHICH ARE THAT: "THE TRUS JOIST <br />SHALL BE ERECTED IN RIGID MODULES AT LEAST 8 FEET <br />IN WIDTH ACCURATELY ASSEMBLED IN A JIG WITH FINAL <br />SHEATHING PERMANENTLY AND TOTALLY ATTACHED WHILE ON <br />THE GROUND. SPECIFIED BRIDGING SHALL BE INSTALLED <br />IN EACH MODULE AS DETAILED". SEE MANUFACTURER'S <br />MANUAL FOR ADDITIONAL REQUIREMENTS. ERECTION, <br />BRACING, AND PROCEDURES, AS WELL AS THE SAFETY OF <br />THE WORKERS, ARE THE RESPONSIBILITY OF THE ERECTOR. <br />D. WEB STIFFENERS: <br />1. COMMERCIAL STRUCTURES: <br />WEB STIFFENERS MUST BE FIELD INSTALLED AT ALL <br />BEARING POINTS AND AT SPECIFIED CONCENTRATED <br />LOADS AS SHOWN ON THE PLANS. WEB STIFFENERS <br />ARE FIELD INSTALLED AT TJI JOIST DEPTHS LESS <br />THAN 22 INCHES AND PLANT INSTALLED <br />THEREAFTER. A GAP BETWEEN THE STIFFENER AND <br />THE TOP CHORD MUST BE PRESENT AT ALL BEARING <br />CONDITIONS. AT CONCENTRATED LOADS THE GAP <br />MUST BE PRESENT BETWEEN THE STIFFENER AND THE <br />BOTTOM CHORD. WEB STIFFENERS SHOULD BE <br />MICRO=LAM LVL OR OF EQUIVALENT STIFFNESS. <br />2. RESIDENTIAL STRUCTURES: <br />IN RESIDENTIAL STRUCTURES WEB STIFFENER <br />REQUIREMENTS (IF ANY) ARE PER THE PLANS AND <br />THE MATERIAL USED SHALL BE PLYWOOD. WEB <br />STIFFENER GAP REQUIREMENTS SHALL BE AS <br />DESCRIBED ABOVE. <br />E. HANGERS: <br />ALL HANGERS SHALL BE AS REQUIRED PER TJI/TJL <br />VENDOR. IT IS THE RESPONSIBILITY OF THE CONTRACTOR <br />TO SEE THAT ANY DISCREPANCIES BETWEEN VENDOR <br />REQUIREMENTS AND THAT WHICH IS CALLED OUT ON THE <br />PLANS BE BROUGHT TO THE ATTENTION OF THE ENGINEER <br />OF RECORD. <br />F. HOLES IN TJI JOISTS: <br />THE TOP AND BOTTOM FLANGES ARE NEVER TO BE CUT. <br />THE JOIST SHALL NOT BE CUT WITHIN 4 INCHES OF <br />THE SUPPORT CENTERLINE OTHERWISE A 1-1/2 INCH <br />DIAMETER HOLE CAN BE CUT IN THE WEB ANYWHERE. <br />ANY SIZE OR SHAPE HOLE LARGER THAN THAT SHALL <br />BE CUT ONLY IN ACCORDANCE WITH THE HOLE CHARTS <br />IN THE MANUFACTURER'S MANUAL AND ON THE PLANS. <br />G. CEILING CLIPS: <br />JOIST / TRUSS CONNECTIONS TO NON -LOAD BEARING WALLS <br />SHALL BE PER THE TYPICAL DETAILS. SLIDE CLIPS <br />SHALL NOT BE USED UNLESS APPROVED BY THE ENGINEER. <br />4.3 PRE-ENGINEERED ROOF AND FLOOR TRUSSES AND P.E. JOISTS <br />(FLOOR JOISTS SHALL BE TRUS JOIST MACMILUAN OR OTHER ICBO <br />APPROVED JOISTS) <br />ALL PREFABRICATED WOOD ROOF AND FLOOR TRUSSES SHALL BE <br />DESIGNED BY OR UNDER THE DIRECT SUPERVISION OF A <br />LICENSED PROFESSIONAL ENGINEER REGISTERED IN THE STATE <br />WHERE THE STRUCTURE IS LOCATED. THE TRUSS SHOP <br />DRAWINGS SHALL BEAR THE STAMP OF THAT ENGINEER. ALL <br />NECESSARY BRIDGING, BLOCKING, PRE -NOTCHED PLATES, <br />HANGERS, ETC. SHALL BE DETAILED OR SPECIFIED, AND <br />FURNISHED BY THE MANUFACTURER. THE TRUSS MANUFACTURER <br />SHALL VERIFY ALL SETBACKS, DIMENSIONS, AND BEARING <br />POINTS PRIOR TO FABRICATION. MAXIMUM ALLOWABLE <br />DEFLECTIONS SHALL BE AS FOLLOWS: <br />FLOOR TOTAL LOAD SPAN/240 <br />FLOOR LIVE LOAD SPAN/360 <br />ROOF TOTAL LOAD SPAN/240 <br />ROOF LIVE LOAD SPAN/360 <br />TRUSSES AND JOISTS SHALL BE DESIGNED FOR THE SPANS AND <br />CONDITIONS SHOWN ON THE PLANS AND SHALL BE FURNISHED AND <br />INSTALLED IN CONFORMANCE WITH THE MANUFACTURER'S PUBLISHED <br />SPECIFICATIONS. ALTERATION OF THE TRUSS OR JOIST LAYOUT <br />INDICATED ON THE PLANS MAY REQUIRE SUPPORTING STRUCTURAL <br />AND FOUNDATION CHANGES, THEREFORE PRIOR APPROVAL BY THE <br />ARCHITECT AND THE STRUCTURAL ENGINEER IS REQUIRED. TRUSSES <br />AND JOISTS SHALL NOT BE FIELD ALTERED PRIOR TO WRITTEN <br />APPROVAL OF THE ENGINEER OF RECORD DESIGNING THE TRUSSES. <br />TRUSS AND JOIST SIZE AND SPACING IS NOTED ON THE PLANS. <br />TRUSS CONNECTIONS TO NON -LOAD BEARING WALLS SHALL BE PER <br />THE TYPICAL DETAILS. SLIDE CLIPS SHALL NOT BE USED <br />UNLESS APPROVED BY THE ENGINEER. <br />4.4 CARPENTRY HARDWARE <br />A. BOLTS SHALL BE ASTM A-307. <br />B. WASHERS SHALL BE STANDARD CUT WASHERS OR MALLEABLE <br />IRON WASHERS. <br />C. ALL NAILS SHALL BE COMMON 'WIRE NAILS OR EQUIVALENT <br />PNEUMATICALLY DRIVEN NAILS (P-NAILS), AMERICAN OR <br />CANADIAN MANUFACTURER ONLY AS INDICATED ABOVE. <br />P-NAILS SHALL BE INSTALLED PER THE MANUFACTURERS <br />GUIDELINES. <br />COMMONWIRE <br />NAIL <br />PNEUMATICMINIMUM <br />NAIL <br />NAIL <br />LENGTH <br />NAIL <br />APPLICAT10N <br />16d <br />COMMON <br />0.162 <br />-NAIL <br />3-172' <br />FRAMING <br />10d <br />COMMON <br />0.148" <br />P-NAIL <br />3-1/4" <br />FRAMING <br />N/A <br />0.131" <br />P-NAIL <br />3-1/4" <br />FRAMING <br />10d <br />COMMON <br />0.148" <br />P-NAIL <br />2-3/8" <br />SHEATHING <br />8d <br />COMMON <br />0.131" <br />P-NAIL <br />2-1/2" <br />SHEATHING <br />D. LAG SCREWS, SHEAR PLATES - SEE UBC. <br />E. ANCHORS AND CONNECTORS SHALL BE SIMPSON, KANTSAG, <br />OR OTHER ICBO APPROVED. <br />F. HARDWARE EXPOSED TO WEATHER OR TO VIEW OR IN <br />UNHEATED PORTION OF BUILDING SHALT_ BE GALVANIZED OR <br />PROTECTED WITH OTHER APPROVED MEANS OF CORROSICN <br />PROTECTION. <br />4.5 MINIMUM NAIUNG - PER 1994 UBC TABLE #23-I-Q <br />4.6 ANCHOR BOLTS <br />PER UBC SECTION 1806.6 ALL FOUNDATION PLATES OR SILLS <br />SHALL BE BOLTED TO CONCRETE OR MASONRY WITH MINIMUM <br />1/2" NOMINAL DIAMETER ANCHOR BOLTS EMBEDDED AT LEAST 7" <br />AND SPACED NOT MORE THAN 6 FEET APART. THERE SHALL BE <br />A MINIMUM OF TWO BOLTS PER PIECE WITH ONE BOLT LOCATED <br />WITHIN 12 INCHES OF EACH END OF EACH PIECE. <br />4.7 OSB / PLYWOOD SHEATHING <br />EACH SHEET SHALL BEAR THE TRADEMARK OF THE AMERICAN <br />PLYWOOD ASSOCIATION. ALL GRADING AND INSTALLATION SHALL <br />CONFORM TO MOST CURRENT VERSION OF APA TECH NOTE N375 <br />FOR OSB. USE THICKNESS AND NAILING AS SHOWN ON THE <br />DRAWINGS. EXCEPT AS OTHERWISE SHOWN OR NOTED, PROVIDE 8d <br />AT 6" ON CENTER ® SUPPORTED PANEL EDGES AND 8d AT 12" <br />ON CENTER ON OTHER SUPPORTING MEMBERS FOR WALLS, ROOFS, <br />AND FLOORS. <br />NOTE: EQUIVALENT RATED PLYWOOD MAY BE USED IN LIEU OF <br />OSB CALLED OUT. ALL THICKNESS AND GRADING SHALL CONFORM <br />TO PS 1. ALL PLYWOOE SHALL BE C-D EXTERIOR GRADE WITH <br />EXTERIOR GLUE. <br />ROOF DIAPHRAGM: 7/16" OSB OR 15/32" PLYWOOD (PANEL INDEX <br />= 24/16), WITH 8d OR 0.131" DIA P-NAIL NAILS AT 6" O.C. AT <br />SUPPORTED PANEL EDGES AND AT 12" O.C. AT FIELD TYPICAL <br />UNLESS NOTED OTHERWISE ON PLAN. USE PLY -CLIPS INSTALLED <br />PER MANUFACTURER'S GUIDELINES ONLY IF SPAN RATING OF ROOF <br />PANELS IS LESS THAN 24/16. <br />FLOOR DIAPHRAGM: 23/32" TONGUE AND GROOVE OSB OR 3/4" <br />PLYWOOD (PANEL INDEX = 48/24), WITH 10d OR 0.148" DIA <br />P-NAIL NAILS AT 6" O.C. AT SUPPORTED PANEL EDGES AND <br />AT 12" O.C. AT FIELD TYPICAL UNLESS NOTED OTHERWISE ON <br />PLAN. SHEATHING SHALL BE GLUE -NAILED TO FRAMING WITH <br />APPROVED ADHESIVE PER THE ARCHITECT. <br />4.8 BLOCKING <br />A. ROOF DIAPHRAGMS SHALL BE UNBLOCKED UNLESS PLANS <br />SHOW OTHERWISE. SOME LOCAL AREAS MAY BE BLOCKED <br />DUE TO HIGHER STRESS CONCENTRATION, BLOCKING SHALL <br />BE DONE BY ONE OF THE TWO METHODS LISTED BELOW: <br />1. ALL PANEL EDGES NOT ON FRAMING MEMBERS SHALL <br />BE CONNECTED WITH STAPLES OR NAILS THROUGH <br />3" WIDE LIGHT GAUGE METAL STRAP PER PLAN. <br />2. ALL PANEL EDGES NOT ON FRAMING MEMBERS SHALL <br />HAVE NOMINAL SOLID WOOD BLOCKING FLAT SIDE <br />FLUSH WITH PANELS AND CONNECTED W/ 0.131"0 <br />P-NAILS. <br />B. FLOOR DIAPHRAGMS SHALL BE UNBLOCKED UNLESS PLANS <br />SHOW OTHERWISE. SOME FLCORS MAY BE BLOCKED, SEE <br />PLANS FOR LOCATION. BLOCK PER PARAGRAPH 4.8.A.1 <br />OR 4.8.A.2 CN SHEET S1. <br />STRUCTURAL T <br />I <br />NOTES CONTINUED <br />ON SHEET S1A <br />SHEET INDEX <br />S1 <br />STRUCTURAL NOTES <br />S1A <br />STRUCTURAL NOTES CONTINUED & DETAILS <br />S2 <br />FOUNDATION PLAN - BLDG. A <br />S3 <br />FOUNDATION PLAN - BLDG. B <br />S4 <br />FOUNDATION PLAN - BLDG. C <br />S5 <br />FOUNDATION PLAN - BLDG. D <br />S5A <br />FOUNDATION PLAN - BLDG. E <br />S6 <br />FOUNDATION DETAILS <br />S7 <br />2ND & 3RD FLOOR FRAMING PLANS - B.DG. A <br />S8 <br />2ND & 3RD FLOOR FRAMING PLANS - BLDG. B <br />S9 <br />2ND & 3RD FLOOR FRAMING PLANS - BLDG. C <br />S10 <br />2ND & 3RD FLOOR FRAMING PLANS - BLDG. D <br />810A <br />2ND & 3RD FLOOR FRAMING PLANS - BLDG. E <br />S11 <br />ROOF FRAMING PLAN - BLDGS. A & B <br />S12 <br />ROOF FRAMING PLAN - BLDGS. C & D <br />S12AI <br />ROOF FRAMING PLAN - BLDG. E <br />S13 <br />DETAILS <br />S14 <br />FOUND, FLOOR & ROOF FKAMING PLAN - REC BLDG. <br />S15 <br />REC. BUILDING DETAILS <br />S16 <br />FOUND. & ROOF FRAMING PLAN - GARAGES <br />And 9 r s Eo n Fl ®y t ICm Structural Engineering Consultants <br />w <br />U) <br />w <br />a <br />w <br />a <br />0 <br />N z <br />ft o <br />o <br />z w <br />¢ a <br />¢ S <br />a 6 <br />s o <br />v/ <br />1�0 <br />ZW Q <br />wI <br />OZ <br />Z W <br />O <br />Uj <br />Z <br />QJ=3 <br />(L < 0 <br />U <br />w <br />OLw <br />W� �2 <br />LuU;0( <br />W <br />cl� Ir <br />0 <br />Vf <br />m <br />x <br />00 <br />m <br />o <br />n <br />LU <br />0 <br />rn <br />M <br />2 <br />N <br />OZ <br />0] <br />LdLLI <br />U <br />o <br />W <br />m <br />a <br />0 <br />LLJ <br />Q� <br />0 <br />Ld <br />Z <br />W <br />L7o <br />0 <br />_0 <br />(n <br />Q <br />0 <br />(� <br />U-) <br />FwLd - <br />o <br />0 <br />SUBMI-TA�A.E <br />ET ONLY <br />NpT,F N`'�1`Ri1CTi0N <br />TH[SE,DRA IJJUBJECT TO <br />R VI SJONS PENDING CAL JURISDICTIONAL <br />RJV W. <br />10101 7"' <br />P <br />t <br />