Laserfiche WebLink
1 <br />r <br />WATTSUN 5.5B PROPOSED/COMPARISON REPORT 11/03/97 <br />FILE: C:\\WATTSUN5\\1546.WS HOUSE ID: <br />Site Address: <br />City, St Zip: <br />Homeowner: <br />Builder: <br />Weather Data: Seattle, WA <br />Climate Zone: 1 <br />Analyst: <br />Jurisdiction: <br />Utility: <br />House Type: <br />Comparis3n File: <br />Heated Floor Area: <br />Single Family <br />1546 ft2 <br />The PROPOSED design *COMPLIES* with 1991 WA State Energy Code. <br />REFERENCE PROPOSED COMPARISON <br />COMPONENT PERFORMANCE 359 344< *** BTU/hr-F <br />ENERGY BUDGET *** *** *** kWh/ft2-yr <br />PROPOSED DESIGN COMPONENTS <br />Component <br />------------------------------------------------------------------------------ <br />Description <br />Value <br />X Area = <br />UA <br />Floor <br />R.11 vented Joist 16oc <br />U-0.056 <br />15-t6 <br />86.6 <br />Glazing @10% <br />**Best Built Vinyl Dbl. Clr. <br />U-0.490 <br />1.61.0 <br />78.9 <br />Doors <br />2gl Half Lite Ins 1/411, Clr <br />U-0.310 <br />21.0 <br />6.5 <br />**Wood 1 3/4",solid flush <br />U-0.330 <br />19.0 <br />6.3 <br />AG Wall <br />R11 STD Lap Wood <br />U-0.088 <br />1252 <br />110.2 <br />Ceiling <br />R30 blown Attic STD baffled <br />U-0.036 <br />1546 <br />55.7 <br />Infiltration <br />Standard Air Sealing <br />ACH-0.350 <br />---------------------------- <br />12368ft3 <br />( 79.2) <br />Proposed <br />UA <br />344 <br />Struc Mass <br />Light Frame, Sheetrock walls <br />M- 3.000 <br />1546 <br />4638 <br />Items in parentheses not included in COMPONENT PERFORMANCE totals. <br />** Denotes non-standard values - check calculation of thermal value. <br />Page 1 <br />