Plan Check q44356 <br />May 16, 1994 <br />2nd Page <br />8. Provide min. 36" landing at exterior entiance or exit. Landing shall not <br />be more than 8" below the finished floor. <br />4. Provide approved fresh air inlets in each bedroom and in each combined <br />Iiving area of the new edition. <br />10. Provide atdc ventilation per Section 3205(c) UBC. Show the net area <br />calculations assuming approximately 753'0 of the vent area is net azea, <br />unless the actual net area is given from the manufacturer. <br />11. All loads aze required to be supported all the way to the foundation. <br />Show all new footings on the foundation plan. <br />In order for the processing of your application to continue, it will be necessary to <br />provide the Building Department with two complete new sets of drawings reflecting the <br />corrections requested. <br />Upon submittal of the drawings, your application will be given priority and plan review <br />will recommence. <br />All required submittals shall be of sufficient detail and contain information to ensure <br />that the proposed structure will be constructed in compliance with all adopted codes. <br />Sincerely, <br />����- <br />Jeffrey HeYlman <br />Development Technician <br />jd/IHpold)56 <br />CITY OF EVERETT• 3200 Cedar Street • Everett, WA 98201 •(206) 259-8800 • Fax (206) 259-8856 <br />