My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9509 7TH AVE SE 2018-01-02 MF Import
>
Address Records
>
7TH AVE SE
>
9509
>
9509 7TH AVE SE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2022 10:55:53 AM
Creation date
4/3/2017 1:18:50 PM
Metadata
Fields
Template:
Address Document
Street Name
7TH AVE SE
Street Number
9509
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
113
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
October 22, 2012 <br />Eagle Countr/ Construction Inc <br />PO Box 1304 <br />Marysville WA 98270 <br />Subject: Project: <br />Sob Address: <br />Plan Check No: <br />Dear Ms. Christensen: <br />Fordham <br />9509 7" Ave SE <br />C1210-001 <br />In response to your application for a construction permit, your plans have been examined and <br />you are advised that the issuance of a permit is being withheld for the reasons listed below. <br />These comments address building issues only. Additional revisions or additions may be <br />required by other departments (such as Utilities, Planning or Fire). All references refer to the <br />(2009 International Building Code,) (2009 International Residential Code,) as amended by the <br />State of Washington and/or Washington State Energy Code 2009 Edition, and adopted by the <br />City of Everett, unless stated otherwise. <br />In order for the processing of your application to continue, it will be necessary to <br />provide the Building Division with two new complete sets of drawings reflecting the <br />corrections requested. <br />1. The "typical 2-ST Section" shows a crawl space, the foundation plan shows slab -on - <br />grade in living space. Please clarify. <br />2. Provide area of all living space (by Floor), garage, covered porches and open decks. <br />3. Remove references to "optional covered deck with gable roof'. Plans shall reflect the <br />proposed structure as it will be built under this specific permit application. <br />4. Show height calculations on elevation drawings. Done elevation for top of concrete at <br />main floor-, top plate at main floor, finished Floor at second floor, top plate at second <br />floor, proposed ridge elevation and maximum elevation per height calculation. (Please <br />be aware that propose structures that are within 12" of the maximum height are <br />required to have the height verified by a licensed Washington State land surveyor). <br />5. Provide section of foundation between the dwelling and the garage. Show rigid <br />insulation with thermal break. <br />CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8800 • Fax (425) 257-8882 J <br />C4lfnmmnn\flndra111NnllmanlflJ lO-fNII /Q9 A Jlh Avn GFI do <br />
The URL can be used to link to this page
Your browser does not support the video tag.