Laserfiche WebLink
Numbered items reference correct;on # from previous letter dated October 22 2012. <br />#2 - The floor area provided does iot match the dimensions shown on the plans. <br />114 - It was requested that the "elevation" be provided at ; <br />Top o' concrete (Elevation) at main floor, finished floor (elevation ) at second floor, top plate (elevation) <br />at second floor, proposed ridge elevation, and maximum elevation per height calculation. Instead the <br />dimensions of the various components were labeled, incorrectly :ailing out a 12" floor system, where <br />14" I -Joists are called out on the framing plans. <br />#5 - The detail shows rigid insulation on the garage side of the foundation instead of in the dwelling. <br />The foundation plan shows a stem wall and a footing not a thickened edge slab on grade. <br />#6 - Rigid insulation should be shown on the foundation plan. <br />#8 - Exterior light fixtures are required to be high Efficacy, not high efficiency. <br />#9 - 5090 of all luminaires are required to be high Efficacy, not high efficiency. <br />#11— An office is considered as a habitable space and is required to be heated. <br />#13 —There is no "Simpson LU8" hanger listed in the Simpson catalog. The LU series of hangers are face <br />mounted with a horizontal seat. The condition shown in the detail will not work with a face mounted <br />hanger with a horizontal seat. <br />