Laserfiche WebLink
9. Provide minimum 18" x 24" crawl spnce access. <br />10. Specify size an�l location of rcquircd foundatioi� vcnts. One vent shall be located <br />witl�in 3'-0" of all cot�ncrs; show on plans. <br />I I. Provide 6 mi1 black vapor barrier, lap edges 12" in crawl space; show on plans. <br />12. Provide ledger detail, sho�v section and elevation � icw. <br />13. Label all rooms (or intended use. <br />14. All braced wall pancls shall be cicarly markecl on plan vicw; RG02.10 IRC. <br />i�. 71�e modifications (wall removal) made to the existing structure causes the esisting <br />building to become non-complying with the requirements of Section R602.10 Wall <br />IIracing. Provide lateral bracing per R602.10 or provide altern�te compliance <br />throual� a stn�ctural analysis prepared by a licensed Washington State Structural <br />�ngineer. <br />16. Show size and type oP all new windows, and how they meet the requirements for <br />escape and mscuc, and light & ventilation per R310 and R303 respectively; as well <br />as Washington State Lnergy Code. <br />17. Provide smoke alarnis per Section R313 iRC; show all locations requimd in ne��- <br />and existin� structure. <br />1S. Sho�i� how new 3.5' x 9.�" LVL beam is supported. <br />19. Show how existing roof raflers and ceilingjoists are supported a[ new 3.5" x 9.S' <br />LVL �eam. <br />20. Sheet A-4.1 refcrenccs Detail Z on Shee[ A-7, but thcre is no Detail #2 on She�:t A- <br />7; please daril'}'. <br />21. All walls 24" wide or larger sliall linvc an oudet such that no point, measured <br />horizontally, sliall Ue more than G trom un outlet. <br />22. "Che section vie�v on Sheet A-7 shows a 3'-S' overhang. The zoning code restricts <br />overl�ings to 18" in a required setback. <br />23. Provide detail of blockin�a between raliers c�pable oP transferrin� rooP loads to the <br />���alls. <br />2�4. Provide detail at roof overhang showing liow fascia and gutters are constructed and <br />attachcd. <br />2�. Pro��idc double top plates with splices lapped 24". <br />26. Provide R-33 insulation in attic over conditioned spaces. <br />27. Provide mininwm 22" x 3-0" attic access with minimum 30" dear over acccss <br />opening. <br />ZS. Sho�� size and focation oCrcyuired attic ventilation per Section RS06 IRC. <br />t_-_'.c.;a I</.,....c Illtf: n1:Iv;10 a',A�a tilil <br />