My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5016 9TH AVE W 2016-01-01 MF Import
>
Address Records
>
9TH AVE W
>
5016
>
5016 9TH AVE W 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/19/2017 9:27:32 PM
Creation date
4/3/2017 2:42:17 PM
Metadata
Fields
Template:
Address Document
Street Name
9TH AVE W
Street Number
5016
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
March I, 2006 <br />'NG/NEER/NG / PUBLIC SERV/CES DEPARTMENT <br />Bill Millcr <br />C009 212'�' Strcet <br />Lynmvood, WA 98036 <br />Subjcct: Project: <br />Job Address: <br />Plan Check No.: <br />Dcar Mr. Millcr: <br />Wchls <br />501 G 9��� ."�vc W <br />C0602-029 <br />In responsc (o your applicalion for a construction pem�it, your plans havc bccn examined and you are <br />adviscd that the issuance of a permit is Ueing withhcid for thc reasons listed below. Thesc conunents <br />address building issues only. Additional revisions or additions may be required by othcr departments <br />asuamencicd,by the State�of Was�hingto i'and/ �11Wasl ington 3tat ��ncrgyCCode�200 CLd t on,,unless <br />stated othenvise. <br />in ordcr for the processing of your �pplication to continue, it will be ne�essary to <br />p►•ovidc the 13uildirng Division witl� hvo complete new sets of dra�vings r,•eflecting <br />�I�c corrections requested. <br />L Revise plans to sl�ow minimum R-21 insulation on tlie interior of below grade walls. <br />2. Stairs are required to be minimum 36" cle�r width, witli R-21 insulation on thc concrete walls. <br />The stairs would have to bc moved over f 6 inches. <br />3. Provide typical scction showing insulation and slairs. Show existing stairs on main level <br />(width). <br />4. Providc stair section and details. Show all components, handrail, rise and run, tteadroom. <br />5. Provide R-10 rigid insulation at perimeter of slab-on-grade where slab is within 24" of the <br />finished gradc. Provide thcrmal Ureak. <br />6. Gcncral construction notes on Sheet "SI" are cut off on left side of pagc. Please provide <br />complete notes. <br />� <br />9. <br />Specify minimum 3%:° thick concrete slab-on-grade in basement. Show on plans. <br />Provide smoke alanns per Section R3 ] 3 1RC. Show requirements on plans. <br />Providc minimum 50 CI�M cxhaust in batliroom. Vent to outside. <br />CITY OF EVERETT • 32C0 C�;dar Street � Everett, WA 98201 •(425) 257-8800 • Fax (425) 257-8856 <br />
The URL can be used to link to this page
Your browser does not support the video tag.