My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5807 12TH AVE W 2016-01-01 MF Import
>
Address Records
>
12TH AVE W
>
5807
>
5807 12TH AVE W 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/4/2017 7:57:00 AM
Creation date
4/4/2017 7:56:54 AM
Metadata
Fields
Template:
Address Document
Street Name
12TH AVE W
Street Number
5807
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, t,�.�.,� , ,� .. <br /> �� ,,� PUBL/l' 6YO.���KS <br /> ::,�,- Eti�E � <br /> � i893•1993 <br /> Febniary 7, 1995 � <br /> Tennyson Homes, Inc. <br /> 815 - 6th St. S <br /> Kirkland WA 98033 <br /> RE: Owner: Tennyson <br /> Job Address: 5807 - 12th Ave W <br /> Plan Check #: C 46770 <br /> Dear Mr. Tennyson: <br /> In response to your application for a construction permit, }�c�ur plans have been <br /> examineci and you are advised that the issuance of a permit is being withheld for the <br /> reasons listed below. These comments address building issues only, additional <br /> revisiens or additions may be required by other departments (such as Jdlities, Planning <br /> or Fire). All references refer to the 1991 Uniform Building Code, as amended by the <br /> State of Washington and /or Washington State Energy Code 1994, lst Edition, unless <br /> stated otherwise. <br /> 1. The columns supporting the 5 I/8" x 16 1/2" glb in the garage must have <br /> mechanical connections at the footing and at the beam to with-stand ]ateral <br /> loading from the floor above. A connection bctween the floor joists and beam <br /> must also be provided to resist lateral loads. This plan is very "open" on the <br /> front side witii few shear resisting elements. You may want to consult x <br /> structural engineer to determine the connector si•�es and attachments. <br /> 2. The foundation vents are not evenl_y distributed. Provide vents adjacent to the <br /> garage on the side and front of the house and provide vents along the front of <br /> the house. <br /> 3. Specify supports for the 6 3/4" x 12" glb suppoRing the second floor. <br /> 4. Provide a fresh air inlet in the family room. <br /> 5. Specify a whole house ventilation fan. <br /> 6. Provide a weather resistive barrier on walls per sec. 1708. Indicate barrier and <br /> siding on wall sections <br /> CITY OF L'VERETi• 3200 Cedar Street• Everett, WA 98201 • (206) 259-8800 • Fax (206) 259-8856 <br />
The URL can be used to link to this page
Your browser does not support the video tag.