Laserfiche WebLink
/ <br /> C I (p5-c�o �v <br /> � <br /> d <br /> Ducl Lcakagc Aflidsvil <br /> Permit#: � �� 6 J��%� T <br /> House address or lot number: <br /> I Uo��l I 2 '�`' I�r � � <br /> Cily: t �.r__� P� Zip: <br /> ^ond. Floor Area (k2): � � �C� Source (circle one): Plan Estimated Measured <br /> ❑ Duct lightness testing is nol required for this residence per exceptions listed at lhe end of this document <br /> Air Handler in conditioned space? �yes'�no Air Har�dler present during test?�Yes❑ no <br /> " \ <br /> Circle Test Melhod: Leakage to Outside _Total Leaka e <br /> Maximum duct leakage: � l�� CFM <br /> Total duct ieakaga air handler installed: (Floor area x .08) _ @25 Pa <br /> Total duct leakage air handler not installed: (floor area x .04) = CFM@25 Pa <br /> Leakage to outdoors: (floor area x .06)= CFM@25 Pa <br /> Test Result: � 6 V� CFM@25Pa <br /> Ring (circle one): O enJ 1 2 3 <br /> DuctBlasterLocation: �f�s�"�ir � ��� �'���'1 PressureTapLocation: G,✓�t�- .FS � 1����"'I <br /> 7" <br /> I certify that these duct leakage rates are accurete and determined using standard duct testing protocol. <br /> Company Name: l.-v Z �—� C.-� 1 i �l ' Technician: ��-� S I.— «1�`�r� <br /> Date: �I � �` I � PhoneNumbei: � ` — � O o' " � � �-� <br /> Washington Slate Energy Code reterence: <br /> 503.10.2 Sealing.All ducls,air handlers,flter boxes,and building cavities used as ducls shall be sealed.Joints and seams shall comply <br /> wilh Seclion M7601.3 of ihe Infomational Residential Code or 603.9 of Ihe Infemational Mechanical Code. D�ct lightness lesting sha'I 6e <br /> conducled to verify that Ihe ducls are sealed.A signed aKdavit dowmenting Ihe test resWts shall be provided to t�ie jurisdic�ion having <br /> aulhority by lhe tesling agent.When required by lhe building otfcial,�he lesl shall be conducted in the presence of depariment stafL �I� <br /> Exceplions: 1.Duc�tigh�ness test is nol required if Ihe air handler and all ducis are localed within condilioned space. �, <br /> 2.Dud tesling is nol required for homes Iess Ihan 1700 square feet o(Ooor area lhat meel all of the following requirements. �, <br /> a)Building cavi�ies ahall not be used as pah ol ihe air transport system. . <br /> b)Porlions of ihe system loca�ed outside of Ihe thermal envelope are limi�ed lo Ihe HVAC equipmenl and no more ihan <br /> 201inear leet of supply and return duct. <br /> c)All equipmen�and duc�located oulside the lhermal envelope shall be sealed using mastic. <br /> d)Filler access insl:.11ed oulside of Ihe thnrmal envelope shall include air-tighl aoors wilh a gasket and a latch. <br /> e)Ducis located outside Ihe Ihermal envelope shall not be insulaled until�he ducl sealing has been inspected.Ducl <br /> insulation inspeclion for lhis section of lhe syslem shall occur at lhe final inspec�ion o!the home. <br />