Laserfiche WebLink
� � � • � <br /> i r „ <br /> Uucl Lcakagc Affida��i� <br /> Permil it: <br /> House address or Iot number. G(J� � � � <br /> City: L- V-fl�� Zip: yo � �.1 U <br /> Cond. FloorArea (kZ): ��v Source(circle onej: lan Estimated Measured <br /> ❑ Duct tightness tesling is not required for lhis residence per exceptions listed at the end of this document <br /> Air Handler in conditioned space9 ❑yes [� no Air Handler present during test7� yes� no <br /> Circle Test Method: Leakage to Oulside Totaf ea a e <br /> Maximum duct leakage: �7C/ � <br /> "fotal duct leakage air handler installed: (floor area x .OS) _ .( J �•oICFM@25 Pa <br /> Total duct leakage air haodler not (nstalled: (floor area x .04) = CFM@25 Pa <br /> Leakage to outdoors: (iloor area x.06)= CFM@25 Pa _ _ <br /> Test Result: l 1 I CFM@25Pa � <br /> Ring (circle ane): Open 1 2 3 <br /> " lDuct Blasler Location:�j,:ZL �I � Pressure Tap Location: /I�/1 �� t- � <br /> I certify that these duct leakage rates are accurate and determined using standard duct testing protocol. <br /> Company Name: l-lJ�� (�1 L°li.� ��'l Technician: "�(I`J GLl =J- �--1 <br /> Date:G� v f � 3 Phone Numbec 3�u U '' `'�3 �- �r/ �' �� <br /> Washington Stato Enargy Codo rofaronca: <br /> 50J.10.2 Soaling.NI ducts,air handlers,fller boxes,and building cavi�ies used as ducls shall be sealed.Joinis and seams shau comply <br /> vnth Section M7607.3 0l Ihe Intemafional Residenfial Code or 603.9 0l the lnlemational Mechanical Code. Ducl tighlness leshng shall be <br /> contlucted lo verify that Ihe tlucls are sealed.A signed alfidavit documeNing the test resulls shalt be provided to lhe jurisdiction having <br /> au!horily by Ihe lesting agenl.When required by the huilding of5cial,Ihe tesl shall 6e conductetl in Ihe presence ol department ctatf. <br /> Ercep6.ons�. t Ouct tighiness test is nol required if Ihe air handler and all ducts are localed within contlilioned space. <br /> 2. Duct testing is not required lor homes less Ihan 7700 square leel of Aoor area Ihat meet all ol Ihe follovnng rEquiremenls. <br /> �)Building wvilies shall nol be usetl as part of Ihe air Iranspoh syslem. <br /> h)Porlions ol lhe system located uutside of Ihe thermal envelope are limiletl lo Ihe HVAC equipment an0 no more than <br /> :0 linear leel of supply and retum duct. <br /> c)NI equipmeN antl tluct localed outside Ihe Ihermal envelope shall be sealed using mastic. <br /> tl)FiLer access instailed outside ol lhe Ihermal envelope shail inclutle art4ight tloors wilh a gaskel antl a lalch. <br /> e)Ducls locatetl outside Ihe thermal en�elope shall not be insul;fed until Ihe ducl seaiing has been inspecletl.Duct <br /> in;ulation inspe:lion for Ihis seclion of Ihe sys�em shall occur a!Ihe final inspection of Ihe home. <br />