My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2909 12TH ST 2018-01-02 MF Import
>
Address Records
>
12TH ST
>
2909
>
2909 12TH ST 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/18/2022 11:07:59 AM
Creation date
4/4/2017 9:35:19 AM
Metadata
Fields
Template:
Address Document
Street Name
12TH ST
Street Number
2909
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
116
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1-12-09 Site visiC by "i ed riudden (Building): <br /> 1. Separate electrical issues and permit requirements (per Tim Alaniz Inspection <br /> report) "Attached" <br /> 2. A Combination permit could be issued for "repairs" subject to Field Inspectioin and <br /> Plan Review approval by Jeff Heilman for Building repairs and Plumbing and <br /> Mechanical corrections--See Plumbing/Mechanical report prepared by S.P. <br /> 1-12-U9 site visit by Shellie Pons (Plumbing): <br /> Corrections: <br /> 1. Water heater rrust be strapped oi anchored per code <br /> 2. Water heater temperature and pressure drain must be piped to the outside <br /> 3. Wasf�er waste vent musC terminate 6" above roof <br /> 4. Union on washer waste P-trap can not be inside the wall <br /> 5. Kitchen sink waste line should be 2" with a 1 1/2" vent to the roof <br /> 6. Ball�tub not vented <br /> 7. Lavatory vent must terminate above roof- 6" <br /> 8. After obtaining rermits, you can contact inspector to discuss ventiny options <br /> 1-12-09 site visit by Shellie Pons (Mechanical) <br /> Corrections: <br /> 1. Exhaust fan for bathroom is not connected through the roof properly <br /> Z. Exhaust fan must be ducted with approved materials and insulated in attic and <br /> otfier cold areas <br /> 3. Uryer vent must ne ducted to code; no corrugated pipe, taped, with no screws <br /> 4. How will heat be provided? Inspector only saav one space heater in living room <br /> 5. Does exhaust fan in kitchen work? <br /> 1-12-09 site visit by (im Alaniz (Electrical): I <br /> Corrections <br /> 1. Electrical wiring installed without permit or inspection <br /> 2. Service modified without permit or insrection <br /> 3. Licensed electrical contractor required to survey complete electrical system and <br /> perform necessary corrections and repairs <br /> 4. New service required <br /> 5. Unpermitted work must conform to Z003 NEC <br /> 6. Existing defects must be repaired <br /> 1-20-09 Application made for "Repair/Correct work done w/o permits" C0901-010. <br /> SNOHOMI5H REGIONAi DRUC,TASK FORCE � <br /> �_ � 1 <br /> ]ONELLE FENTON-W.4LIACE � <br /> Environmenr�l Heald� Specialisr <br /> !� SNOHOMISH Ccll (4.^.5] 754-0908 <br /> � ' n �HEALTH FAX (360) 658J664 <br /> �DISTRICT /FW��snoro.o:g <br /> 3000 Rockefeiler • Mi5 #606 • Everett, WA 98201 <br /> (4251 388-3 4 79 <br /> Pa�c ? ��� _' <br />