Laserfiche WebLink
. ,BLIC WORKS PERMIT COMIVIE� � <br /> 4. Connect side sewer per City Standard 11F01. <br /> �,�i Connect side sewer per City Standard#'s 601, 602, 604. <br /> 6. Connect all rooflop downs��ouls to thr,side se„er. <br /> �� ` Connect rouftop downspouls to the drainage syslem provided for this lot. <br /> ,, Rooftop runoff must be disr.harged to a rooi downspout infillration system per Ciry of Everett Storm <br /> Manuai 3-2.6.2. The approximate size lrench is 3.5' wide, 2'deep and 25' long. See atlachment for <br /> more details. <br /> 9. The contractor must meet with the Public Works Inspector tc discuss potential drainage routing prior to <br /> beginning the project. <br /> . y� 10. Install erosion conUol measures as delermined by the Public Works inspector, suc�� as silt fence, siraw <br /> � � bales, swales, or erosion blankels. <br /> 11. Inslall erosion control measures per Cily of Everelt Standards for small parcels <br /> �12 Remove erosion conL•ol measures upcn completion of the project prior to final approval of the permit. <br /> �13. All excavated material from foundalic�, sidewalk and driveways shall be hauled to an zpproved, <br /> permilled site. No wasting of malerial is allowed un this build na lot. <br /> �14.; No dirt, mud, rocks or debris to be tracked onlo roadway. <br /> • 15. No building materials to be stacked on sidewalks and sidewalks tc l�e kept clean and open for <br /> pedestrian trevel. <br /> 16. Adjust waler meter box 1" above sidewalk grade. <br /> 17. �emove and replace curb, gu!ter and sidewalk as per Cily u( E��erell Standard Plan ;;'s 305A& 30f on <br /> this proposal's fronlage as direcled by the Public Works Inspector (i.e. all unused driveways and any <br /> u�oken or damaged area musl be replaced). <br /> 18. Install a Type I concrete driveway per City oi Everetl Standard #307. <br /> 19. Pave driveway from the front property line out to the street paving. <br /> 20. Conlacl the / /C/i '�:�%i r' �_Waler Districl(or connecling provisions for lhis building's �,valer and <br /> � sewer services. <br /> 21, A catch basin as per City Standard Plan tW02 'Nith a gas trap per Standard Plan�t410 is required for the <br /> parking area. <br /> 22. If a sewer pump system is to be inslalted, the pressure line must discharge into a private manhole, then <br /> gravity ilow across ihe public right-of-way. <br /> �3. A sprinkler system is required for this building in compliance wilh the requirements of NFDA Standards <br /> 13D <br /> FOR 1=UBLI(' WORf<S INSPECTION, CALL RANDY AT 425-339-7A03 / CLIFF AT 425-339-7d04 <br /> P'ilScnm�a<� � � <br /> ����� <br />