My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9415 18TH AVE W 2016-01-01 MF Import
>
Address Records
>
18TH AVE W
>
9415
>
9415 18TH AVE W 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/19/2017 5:41:41 PM
Creation date
4/4/2017 3:27:50 PM
Metadata
Fields
Template:
Address Document
Street Name
18TH AVE W
Street Number
9415
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
80
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I���� <br />��;'1I�� I <br />C�3�3 -u�Z <br />rRuss oms�oM <br />2061567"� Avenue, Arli.iglon, WA 96223 3G0-925-4755 <br />Warnings: <br />1. READ ALL GENERAL NOTES AND WARNINGS BEPORE ERECTION O(= TRUSSES. <br />2. BUILDER AND ERECTION CONTRACTOR MUST READ ALL GENERAL NOTES AND VJARNINGS <br />BEFORE ERECTION OR INSTALLATION OF TRUSSES COMMENCES. <br />3. COMPRESSION WEB BRACING MUST BE INSTALLED WHERE INDICATED BY � ON TFIE <br />TRUSS ENG�NEERING. <br />4. ALL LATERAL FORCE RESISTING EL[MENTS SUCH, AS TEMPORARY AND PERIdANENT <br />BRACING, MUST BE DESIGNED BY THE DESIGNER OF THE GOMPLETE STRUCTURE. <br />ProBuild's TruSS Division ASSUMES NO RESPONSIBiLITY FOR SUCH BRACING. <br />5. NO LOAD SHOULD BE APPLI[D TO AIJ'f COMPONENT UNTIL AFTER ALL BRACING AND <br />FASTENERS ARE COMPLETE AND AT NO TIME SHOULD ANY LOAD GREATER THAN DESIGN <br />LOADS BE APPLIED TO ANY COMPONENT. <br />6. MITEK HAS NO CONTROL OVER AND ASSUMES NO RESPONSIBILITY FOR TI;E <br />FABRICATION, HANDLING, SHIPMENT AND INSTALLATION OF COMPON[NTS. <br />7. THESE DESIGNS ARE FURNISHED SUBJECT TO THE LIMITATIONS ON TRUSS DESIGNS SET <br />FOR?H BY THE TRUSS PLATE IVSTITUTE IN "BCSI•B1 SUMMARY SHEET — GUIDE FOR <br />HANDLING, INSTALLING AND BRACING OF METAL PLATE CONNECTED WOOD TRUSSES" A <br />COPY OF WHICH IS NTTACHED. <br />a. DO NOT INSTALL DAMAGED OR BROKEN TRUSSES. <br />9. DO NOT CUT, ALTER OR DRILL ANY CHORD OR VJEB MEMBER OF TH[ TRUSS. <br />Genera/ Notes, Unless Noted Otherwise <br />TRUSSES DESIGNED TO SUPPORT LOADS AS SHOWN ON TRUSS ENGINEERING. <br />2. TRUSS DESIGN ASSUMES THE TOP AND BOTiOM CHORDS TO BE LATERALLY BRACED NT <br />2'-0" o.c. AND AT 10'-0" o.c. RESPECTIVELY UNLESS OTHERWISE NOTED. <br />3. 2X4 IMPACT BRIDGING OR LATERAL BRACING RECOMMENDED WHERE SHOWN BY � <br />ON THE TRUSS ENGINEERING. <br />4. INSTALLATION OF TRUSS IS THE RESPONSIBILITY OF THE RESPECTIVE CONTRACTOR. <br />5 T I�USS DESIGN ASSUMES TRUSSES ARE TO BE USED IN A NON-CORROSIVE <br />[NVIRONMENT AND ARE FOR "DRY CONDITION" OF USE. <br />6. TRUSS DESIGN ASSUMES FULL BEARING ATALL SUPPORTS SHOWN. SHIM OR WEDGE IF <br />NECESSARY. <br />7. "TRUSS DESIGN ASSUMES ADEQUATE DRAINAGE IS PROVIDED. <br />6. PLATES SHALL BE LOCATED ON BOTH FACES OF TRUSS AND PLATED SO THEIR <br />CENTERLINES COINCIDE WITH JOINT CENTERLINES. <br />9. DIGITS INDICATE SIZE OF PLATE IN INCHES. <br />70. FOR BASIC DESIGN VALUES OF MITEK PLATE, INDICATED BY THE PREFIX "MII", <br />SEE ICC ESR-1311. <br />11. THE MITEK NET SECTION PLATE HAS THE SUFFIX "HS", THE DESIGNATOR (18) INDICATES <br />1A GA. P,4ATERIAL IS USED. ALL OTHERS ARE 20 GA. <br />
The URL can be used to link to this page
Your browser does not support the video tag.