Laserfiche WebLink
� Node ID: RPL Vault <br />Desc: Manhole structure <br />� Start EI: 100.0000 ft Max EI: 105.0000 ft <br />Storage Id: Vault Discharge Id: Flow Control <br />Node ID: Vault <br />Desc: Manhole structure <br />Start EI: 100.0000 ft Max EI: 105.0000 ft <br />Length Width Void Ratio <br />36.0000 ft 22.4600 ft 100.00 <br />Correction Factor adjustment 22.46 x 1.38 = 31.0 wide <br />Control Structure ID: Flow Control - Multiple Orifice Structure <br />Descrip: Multiple Orifice <br />Start EI Mas EI Increment <br />100.0000 ft 106.0000 ft 0.10 <br />Orif Coeff: 0.62 Dottom EI: 98.00 N <br />Lowest Diam: 0.5566 in <br />out to 2nd: 5.4000 tt Diam: 3.8750 in <br />RLPCOMPUTE [RP� Vault] SUMMARY <br />2 yr Match Q: 0.0197 cfs Peak Out Q: 0.0195 cfs - Peak Stg: 105.40 ft - Active Vol: 0.10 acft <br />10 yr Match Q: 0.1386 cfs Peak Out Q: 0.1157 cfs - Peak Stg: 105.46 ft - Active Vol: 0.10 acft <br />100 yr Match Q: 0.3354 cfs Peak Oul Q: 0.32f11 cfs - Peak Stg: 105.97 ft - Active Vol: 0.11 acft <br />