PROJECT GENERAL NOTES l V i a oMr- <br /> ��1D 8g o❑0,M <br /> GENERAL REQUIREMENTS & DESICaN CRITERIA TON '°mo <br /> ♦ 'W J Z Fa <br /> BUILDING CODE: 2012 INTERNATIONAL BUILDINGCODE(IBC) � a '` � m 3 NN <br /> NN <br /> • STRUCTURAL RESPONSIBILITIES:THE ENGINEER IS RESPONSIBLE FOR THE STRENGTH AND z J N d U)Z N N <br /> ^o ti Q 2 � � as <br /> 5.... <br /> STABILITY OF THE PRIMARY STRUCTURE IN ITS COMPLETED STATE. <br /> �G <br /> CONTRACTOR RESPONSIBILITIES:THE CONTRACTOR IS RESPONSIBLE FOR THE MEANS AND �� r 4 ' L�, C��j N N Y <br /> METHODS OF CONSTRUCTION AND ALL JOB RELATED SAFETY STANDARDS SUCH AS OSHA AND cis I`-u. <br /> LLSHA. THE CONTRACTOR 15 RESPONSIBLE FOR THE STRENGTH AND STABILITY OF THE -- `� W I <br /> STRUCTURE DURING CONSTRUCTION AND SHALL PROVIDE TEMPORARY SHORING,BRACING AND 28'-4"t(FIELD VERIFY) 11 <br /> IL <br /> OTHER ELEMENTS REQUIRED TO MAINTAIN STABILITY UNTIL THE STRUCTURE 15 COMPLETED. IT 15 V j <br /> THE CONTRACTOR'S RESPONSIBILITY 70 BE FAMILIAR WITH THE WORK REQUIRED IN THE ui Z o <br /> CONSTRUCTION DOCUMENTS AND THE REQUIREMENTS FOR EXECUTING IT PROPERLY. W Q u <br /> rr^^ J J <br /> DISCREPANCIES: IN CASE OF DISCREPANCIES BETWEEN THE PROJECT NOTES,DRAWINGS,AND/OR VJ 41 J C <br /> EXISTING CONDITIONS,ENGINEER SHALL DETER llNE WHICH GOVERNS. DISCREPANCIES SHALL BE (E)H TO W J D <br /> BROUGHT TO ATTENTION OF ENGINEER BEFORE PROCEEDING WITH THE WORK. THE CONTRACTOR (' v <br /> SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO FABRICATION AND <br /> CONSTRUCTION. CONFLICTS BETWEEN THE DRAWINGS AND ACTUAL SITE CONDITIONS SHALL BE I I I I 14= E)4HDR ,7 H <br /> BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE PROCEEDING WITH THE WORK. REMAIN I <br /> Y <br /> I I I I I I I ) I i I I I Ip > <br /> (E71�x�41EXT.W��++LLLS LO <br /> WIND DE51GN I I I TO RenAIN,TV'F UNOI I I I I Q R <br /> BASIC WIND SPEED(3-SEC GUST) v= 110 MPH OCCUPANCY CATEGORY 11 -0 0 LL L LEXPOSURE CATEGORY B INTERNAL PRESSURE COEFF.,GCpI t0.18 a v w wLl 3 <br /> '? <br /> SEISMIC DESIGN <br /> � W <br /> NO CHANGE, <br /> e snL <br /> SNOW LOAD rn LyJ �n <br /> GROUND SNOW LOAD,Pg 20 PSF FLAT ROOF SNOUT LOAD,Pf 25 PSF I I I I I I I I I I I r Ln r <br /> SNOW EXPOSURE FACTOR,Ce 1.0 THERMAL FACTOR,Ct 1.0 <br /> INSPECTIONS BY BUILDING OFFICIAL:ALL CONSTRICTION 15 SUBJECT TO INSPECTIONS BY THE <br /> BUILDING OFFICIAL IN ACCORDANCE WITH IBC SEC 110. THE CONTRACTOR SHALL COORDINATE Q <br /> ALL REQUIRED INSPECTIONS WITH THE BUILDING OFFICIAL. SUBMIT COPIES OF ALL INSPECTION I p <br /> REPORTS TO THE ENGINEER FOR REVIEW, w - Lu <br /> Lu <br /> u Q > LJJ ? <br /> WDOD FRAMING I I I (L p IV c(i N IL <br /> STANDARDS: IBC CHAPTER 23,NDS AND NDS SUPPLEMENT Imo 8Iw I I N <br /> IDENTIFICATION:ALL SAWN LUMBER PRODUCTS SHALL BE IDENTIFIED BY THE GRADE MARK ORA <br /> CERTIFICATE OF INSPECTION ISSUED BY THE CERTIFYING AGENCY. N x4 m 'I I x N x I I I I I <br /> MATERIALS: WA F M I wlR O 'r m (N RY <br /> SAWN LUMBER:CONFORM TO GRADING RULES OF WWPA,WCLIB OR NLGA.FINGER JOINTED H A AG� DO ,U= O Z N <br /> STUDS ACCEPTABLE AT INTERIOR WALLS ONLY. I w L <br /> MEMBER USE SIZE SPECIES GRADE 0. <br /> STUDS a POSTS 2x,4x HEM-FIR NO.2 WHERE( R TAU- -� I I L�t <br /> ( )T6/5 T�. wJ015TS+RAFTERS 2x6-2x12 HEM-FIR NO.2 DAMAG D R(N x4 I I I 7 ® <br /> BEAMS 4x8-4x12 HEM-FIR NO.2 SA UT�t TO xIST N 2/9FN7 3 I I (N-THDOF @-AMS I I (K <br /> WOOD STRUCTURAL SHEATHING(PLYWOOD):WOOD APA-RATED STRUCTURAL SHEATHING <br /> INCLUDES:ALL VENEER PLYWOOD,ORIENTED STRAND BOARD,AND COMPOSITES OF (E)DAMAGEDFT <br /> VENEER AND WOOD BASED MATERIAL. CONFORM TO PRODUCT STANDARDS PS-1-95 AND TAILS <br /> PS-2-92 OF THE U.S.DEPT.OF COMMERCE AND THE AMERICAN PLYWOOD ASSOCIATION ../ (ti ^. 3.-.D "Zt7 z6 (E)HIR TO <br /> (APA). 1 HDR /SNI 3', REMAIN <br /> MINIMUM APA RATING <br /> LOCATION THICKNESS SPAN RATING PLYWOOD GRADE EXPOSURE `^ - [U <br /> ROOF 15/32" 32116 C-D 1 d�?'� (E)EDGE OF Z Q W •- <br /> WALLS 15/32° 32/16 C-D 1 +°'tea' QF r —-- - U J '.EL O <br /> WALLS(AL7) 7f6"05B 24/16 G-D i ?�+b�y0 (N14x6 PORCH - --- 5/SHT3 �_ W Q N <br /> JOIST HANGERS AND CONNECTORS:SHALL BE"STRONG TIE"BY SIMPSON COMPANY OR USP �� ��• ROOF BEAMS � <br /> EQUIVALENT AS SPECIFIED IN THEIR LATEST CATALOGS. CONNECTORS SHALL BE INSTALLED )�{e - - (E)2x4 PORCH (J] '� Ld p� <br /> ROOF W <br /> PER THE MANUFACTURER'S INSTRUCTIONS. WHERE CONNECTOR STRAPS CONNECT TWO � - - - TOO REMAIN, P � � Q Q <br /> MEMBERS,PLACE U2 OF THE NAILS OR BOLTS IN EACH MEMBER. PROVIDE WASHERS UNDER <br /> THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. UNLESS NOTED (E)4x4 PORCH POSTS TO REMAIN- Q m 3 <br /> OTHERWISE ALL NAILS SHALL BE FULL LENGTH COMMON. PROV(2A,`0 x 6"SDS _ _ FASTEN(N)BEAMS TO TOP OF <br /> NAILS AND STAPLES:CONFORM TO IBC SEC 2303.6"NAILS AND STAPLES."UNLESS NOTED SCREWS THRU(E)POST (E)POST W/'ACE4'POST CAPS C) Qa, N F- <br /> ON PLANS,NAIL PER IBC TABLE 2304.9.1. UNLESS NOTED OTHERWISE ALL NAIL5 SHALL BE OR(N)4x6 BEAM INTO L!1 W <br /> COMMON. NAIL SIZES SPECIFIED ON THE DRAWINGS ARE BASED ON THE FOLLOWING (E)2?(AT FRONT SOFFIT. N '0 a <br /> 5'-il"t <br /> SPECIFICSIZE ATIOJS I ENGTH DIAMETER TYP EA SIDE OF PORCH W <br /> ad 21/2" 0.131" ED <br /> 10d 3" 0.148" PLAN NOTES: ILL <br /> 16d 31/2" 0162" I. ALL DIMENSIONS ARE APPROXIMATE TO FACE OF STUD FRAMING. CONTRACTOR U <br /> LAG 5OLT5BOLT5:CONFORM TO ASTM A301. SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION N CONSTRUCTION, <br /> 2. SAFETY GLASS 18 REQUIRED PER IRC SECTION R308A. <br /> NAILING REQUIREMENTS:PROVIDE MINIMUM NAILING IN ACCORDANCE WITH IBC TABLE 2304.9.1 3. ALL WOOD FRAMING WITH SURFACE CHAR LESS THAN'e"MAY REMAIN IN PLACE � <br /> "FASTENING SCHEDULE"EXCEPT AS NOTED ON THE DRAWINGS. NAILS SHALL BE DRIVEN FLUSH PROVIDED IT IS CLEANED BY MECHANICAL MEANS AND SMOKE SEALED,ANY CL <br /> AND SHALL NOT FRACTURE THE SlJRFACE OF SHEATHING. WOOD FRAMING WITH DAMAGE GREATER THAN 40"MUST BE REMOVED AND <br /> REPLACED IN-LIKE KIND TO MATCH EXISTING SIZE i SPACING. W <br /> STANDARD LIGHT-FRAME CONSTRUCTION:UNLESS NOTED ON THE PLANS,CONSTRUCTION SHALL 4. ALL WOOD FRAMING THAT IS FOUND TO BE SPLIT,FRACTURED,MISSING ANY <br /> CONFORM TO IBC SEC 2308"CONVENTIONAL LIGHT-FRAME CONSTRUCTION"AND IBC SEC 2304 PORTION OF ITS CROSS-SECTION OR OTHERWISE MATERIALLY DEFORMED OR L9 Z <br /> "GENERAL CONSTRUCTION REQUIREMENTS." OUT-OF-PLUMB SHALL BE REMOVED t REPLACED WITH NEW FRAMING OF LIKE KIND Qj Q V U] <br /> AND SIZE TO MATCH EXISTING. USE MIN HEM-FIR•2 OR BETTER UNO ON PLANS. Q < L3 W <br /> MOISTURE CONTENT:WOOD MATERIAL USED FOR THIS PROJECT SHALL HAVE MAXIMUM MOISTURE 5. ALL REPLACEMENT GWB SHALL BE II,,"THICK REPLACEMENT EXTERIOR SHEATHING m W <br /> CONTENT OF 19%EXCEPT FOR THE PRESSURE-TREATED WOOD SILL PLATE. SHALL MATCH EXISTING,HOWEVER,SHALL BE AT LEAST 15/92"OSB OR PLYWOOD V" m Z ❑ ❑ <br /> FOR ROOF AND 085 OR 15/32°PLYWOOD FOR WALL SHEATHING. UNO,NAIL 8d Q W m Z <br /> PRESERVATIVE TREATMENT:WOOD MATERIALS ARE REQUIRED TO BE"TREATED WOOD"UNDER �6 :--- ❑ d UI IL <br /> 6"OC AT PANEL EDGES AND 12"OC FIELD NAILING. W W <br /> CERTAIN CONDITIONS IN ACCORDANCE WITH TBG SEG 2304.11"PROTECTION AGAINST DECAY AND 6. PROVIDE NEW KRAFT-FACED R-49 ATTIC BATT INSULATION t NEW KRAFT-FACEDR-15 <br /> LLI ❑ <br /> TERMITES". CONFORM TO THE APPROPRIATE STANDARDS OF THE AMERICAN <br /> WOOD-PRESERVERS ASSOCIATION(AWPA)FOR SAWN LUMBER,GLUED LAMINATED TIMBER,ROUND SIN INSULATION AT 2x4 EXIST EXTERIOR WALLS WHERE DAMAGED. T LIEU OF <br /> U <br /> POLES,WOOD PILES AND MARINE PILES. FOLLOW AMERICAN LUMBER STANDARDS COMMITTEE USING KRAFT-FACED BAT TS WHERE INDICATED ABOVE,UNPAGED BAT6 MAY BE <br /> FAINT WITH A <br /> (ALSC)QUALITY ASSURANCE PROCEDURES.PRODUCTS SHALL BEAR THE APPROPRIATE MARK USED PROVIDED THAT A VAPOR RETARDING PRIMER OR FINISH <br /> PERMEABILITY RATING LESS THAN OR EQUAL TO MAY BE USED. <br /> METAL CONNECTORS/PT WOOD:GK5E RECOMMENDS THAT ALL METAL HARDWARE AND 7. ANY NEW GLAZING SHALLL AN USED, <br /> MEET MIN.U=090(VERT)AND U•0,50(OVERHEAD). <br /> FASTENERS IN CONTACT WITH PRESSURE TREATED LUMBER BE STAINLESS STEEL TYPE 316L. AT 8, ANY NEW EXTERIOR DOORS SHALL BE MIN U•030. <br /> THE OWNER'S RISK AND DISCRETION,HOT-DIPPED GALVANIZED METAL HARDWARE AND <br /> FASTENERS MAY BE INVESTIGATED FOR USE IN LIEU OF STAINLESS STEEL PROVIDED THAT THE ROOF FRAMING REPAIR PLAN <br /> FINISH HAS A MINIMUM ZINC CONTENT OF AT LEAST 1.85 OZ/SF AND ITS USE 15 COORDINATED BY <br /> THE CONTRACTOR AND WOOD SUPPLIER FOR THE EXPECTED ENVIRONMENT AND MOISTURE <br /> EXPOSURE FOR APPROPRIATE USE BASED ON THE METHOD OF PRESERVATIVE TREATMENT OF SCALE:1/4"•I'-0" D F 3 <br /> THE WOOD. <br />