Laserfiche WebLink
Simple Heating System Size: Washington State <br /> This heatinp svstem sizinq calculator is based on the Prescriptive Requirements of the 2012 Washinqton State EnerqV Code(WSEC)and ACCA <br /> Manuals J and S.This calculator will calculate heatinq loads onlv.ACCA procedures for sizinq coolincLsvstems should be used to determine coolinq <br /> loads. <br /> The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of <br /> 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section, <br /> some values will be calculated for you. If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension <br /> Program at(360)956-2042 for assistance. <br /> Project Infomiation Contact Information <br /> Unit E3 Townhome Polygon Northwest <br /> Silver Lake Townhomes Alaina Robertson <br /> Everett,Washington (425)606-0005 <br /> Heatinq Svstem Type: OO Fo��ed A��F���a�e Q Heat Pump <br /> To see detailed instructions for each section,place your cursor on the word"Instructions". <br /> Desiqn Temperature <br /> �"`ef1°�101`> - � Design Temperature Difference(oT) 47 <br /> t�Cre.tt)(, � oT=Indoor(70 deyrees)-Oufdoor Design Temp <br /> .,,r t+ ,......:... <br /> Area of Buildinq <br /> Conditioned Floor Area <br /> i��;i��,�i��,,;-; Conditioned Floor Area(sq ft) 1,585 <br /> Average Ceiling Height Conditioned Volume <br /> ",`r'�`"`t'°"`; Average Ceiling Height(ft) 8.5 13,473 <br /> Glazinq and Doors U-Factor X Area = UA <br /> �"`'"""'>"". 0.30 269 8070 <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> b,��.;�,��:r�,��-. -� � 0.026 263 6.84 <br /> R�49 ......... � <br /> � �.., <br /> Single Rafter or Joist Vaulted Ceilings U-Factor Area UA <br /> i�,�.i���ct�����,: �. � � <br /> �, tao Ve��ICd COiI�ng51i1 th�s proJ@Ct. <br /> --- <br /> t.. w�..:�yi. <br /> Above Grade Walls(seeFiyure�) U-Factor Area UA <br /> �,,�.n;�,.in,���, .""'.,"`�..."".""" i 0.056 528 29.57 <br /> R-21 � <br /> Floors � � U-Factor Area UA <br /> �n:;tructions .... ,,�_..__.__ .__,_ ._.. � <br /> ,�.}�, . 0.029 379 10.99 <br /> � <br /> Below Grade Walls�SeeF�g�.e+J U-Factor Area UA <br /> i�w�����.���,�_. - . � 0 <br /> '� No(3�layv Grddc 1Valls!n t1�is Pro�ec.L � --- --- <br /> Slab Below Grade�5ee Fro�re n F-Factor Length UA <br /> �,�e,;ructlon; `_ _—. � <br /> "' <br /> , '.c Slala tielow GrdC.k�nt thi;pro;eCL � <br /> Slab on Grade�SeeFrq�.e n � � F-Factor Length UA <br /> �"`'t''"��10"' "� � -�' 0.540 81 43.88 <br /> � iz�ioFe��rete� - � � <br /> _�..,�`�.rJ <br /> Location of Ducts <br /> °i�'"`°`"'°° Duct Leakage Coefficient <br /> ConciGrneil Space � <br /> ��.�__..__...__.. .__�. -�...,...,��:....._:____.__ 1.00 <br /> Sum of UA 171.97 <br /> Envelope Heat Load 8,083 Btu/Hour <br /> Fipure 1, s�,��oruaxnr <br /> Air Leakage Heat Load 6,839 Btu/Hour <br /> ""�~N�_�.,, Volume X O.G X AT X.018 <br /> abo�e��aae Building Design Heat Load 14,921 Btu/Hour <br /> <g„�, : � � � � Air Leakage+6nelope Heat Loss <br /> � � Building and Duct Heat Load 14,921 Btu!Hour <br /> Ducts in uncondilioned space:Sum o/Building Heat Loss X 1.10 <br /> Ducts in condifioned space:Sum oBuilding Heat Loss X 7 <br /> Maximum Heat Equipment Output 20,890 Btu/Hour <br /> Budding and Duct Heat Loss X 1.40 lor Forced Aii Fumace <br /> Building and Ducf Heaf Loss X L25 for Heat Pump <br /> ( � - : <br /> � (07/01/13) <br />