Laserfiche WebLink
j��,1,¢Ramns_ —�- � <br /> ___ -- --- - -- — -- ----- <br /> Inside Ramv N MIA�here YES NO <br /> R311.6.1 Maximum Slope one unit vertical in t,velve units honzontal (8.39'o slope). C � <br /> R311.6.2 Landing Requlrements: min. 3X3 foot landing at top/bottom, where doors open onto � � <br /> ramps, and wheie ranip changes directions. <br /> R311.6.3 Handrails required (p�tti3id�aof ramo:cer5Wtel�sers�na ream�mept WAC 388-76-10730). ❑ ❑ <br /> Outside Ramv M WA 0 here� YES NO <br /> R311.6.1 Maximum Slope one unit vertical In twelve units horizontel (83°Yo slope). � � <br /> R311.6.2 Landing Requirements: �nin. 3X3 foo[ Ianding at top/bottom, where doors open onto � � <br /> remns, and where ramp changes directlons. <br /> R311.6.3 Handrails required (pnJ�ih3isl�aft�mo cer aate IicMM+�na ieau�mept WAC 388-76-10730) ❑ ❑ <br /> '•Guards below are de icted vertiw��y as an example oN�___ _ _ ________________ <br /> i�,sm.�.- <br /> Handrailllnlh siA�� <br /> 3�'-7G' <br /> Guant j <br /> ill'nun � i <br /> I <br /> i I ' <br /> i <br /> � . - - -I . . . i . •i'rnin <br /> 1'� 1'm�n ` - . _ . . � ' . . . _. . . . . . . , I la tl�np <br /> Ian��inR . . . . — _- . . . <br /> — — 1 17 ma�+lon� • <br /> t 3' � <br /> � �. � P iM t� <br /> �,,,, . � r F=':�I _ � H �.�E i . , <br /> , , , _ . . II . �.iri , .,l -' L .. '.'C . ` . <br /> ' �II I ' F : �II F_ - II .' . c .' ' ' <br /> R311 Mean,of Earnss YES NO <br /> R311.4.2 Door Type and Size: Side-hinged not I�s lhan 3 feet in width and 6 feet 8 inches In heigh4 ❑ ❑ <br /> R311.4.4 Type of lock or latch: readily openable from the side from which egress Is to be made without � � <br /> the use of a key ur speoal knuwledae or effort ,_ <br /> R311,5 Stalrwavs fl rUA�here___YES_ NO <br /> R311.5.3.1 Hiser Hei9ht Max riser height shall be 7'/� mthes (0 inches m stmclures budt pna to Jitly 1,2004) ❑ ❑ <br /> R311.5.3.2 Tread Uepth: Min. lread depth shall be 14�nsht�. (9 inches in slmctures built pna ro July 1.2004) ❑ � <br /> R311 5 6 r+andrails required on both siAes of o�e nser a more(osr state hce��vna reaur�t wnc 3ee-�b-im�o) ❑ _ � <br /> Grab Bars in Bathrooms YES N0. <br /> WAC 38846-10730 The A�H must mstall and securely fasten grab bars (not suction cup style) to meet the ❑ O <br /> nceds ol resiAents in: <br /> 8athing facilitles such as tubs and shuwers; and � p <br /> On both sides of the toilet (if structurally not feasible use type that affix to tollet seat) � � <br /> A,�C,101 Swimminy Pool„��. Not Tub _ ___ B WA�here YES NO_ <br /> AG105 Must be surrounded by a barrier that is 48 inches hi�h, may have doors and or gates that � � <br /> must have audible alarms when opened. <br /> AGIOS S EXCEPTION• Spas or hot tubs with a salely cover which complles with ASTM F 1346 ❑ � <br /> ❑ PASSED ❑ CORRECTIONS REQUIRED ❑ PERMIT REQUIREO <br /> INSPERON'S SIGN�7VNE: DATE: <br /> INSPER00.'S ADDRE55: ' <br /> Apphrabnn antl Inspec�ion Checwlist develoDed by Washington AssociaUon of Budding 011¢ials (WABO�. <br /> �n cuopeiat�on w�th Depailmant al Social and Heallh Serv�ces �DSH;) lor use by both deparlmente and licensors <br /> BH 109 <br />