Laserfiche WebLink
l . _ r �- <br /> . � <br /> Ltr. Kelly Heath <br /> March 29, 2001 <br /> Re: 2520 100ih Street SE <br /> t 7. Provide a landing at alI entrance/exits. The landing shall be at leas! as widc .,s the door <br /> and not less than 36" in the direction of travel. The landing shall be not more than 8" <br /> below the finished floor. <br /> � 8. The foundation plan for the garage show 2'-10 �h" returns, but the floor plan shows 2'- <br /> 8". Please correct. <br /> l9. Provide size species and grad� for all headcrs in garage. <br /> VIO. Provide solid blocking over intermediate support in crawl space. <br /> �l 1. Provide insulation baffles per Section 502.1.4.5 Wa. St. Energy Code (W3EC). Show <br /> on plans. Baffles shall extend 6" vertically above batts and 12" vertically above loose <br /> fill insulation. <br /> '�12 Show calculations for attic ��e:itilauon on plTns. <br /> '�13. 5pecify sn�J size and omcenter spacing m garage walk. <br /> �I4. Plans show R-13 insularion �n :'. � h walls Please clarify. <br /> ✓5. P�•o�idc douhle top plate, lap s;lices 48". Sl�ow on plans. <br /> ✓16.Specify minimum SU cfm fan in new bathroem and laundry. <br /> 17. Specify smooth hard non-abs,nhent rnaierial in bathtub/shower srea. <br /> Prepare a response lener showing where each item in this correc[ion letter is addresseJ on tl�e plan <br /> set. <br /> Upon resubmittal of the drawings, your application will be given priority and plan review will <br /> recommence. <br /> All required submittals shall be of sufficient detail and contain sufficient information tu ensure that <br /> the proposed structure will be conswcted in compliance with all adopted codes. <br /> Sincerely, � <br /> Jeff Iie man <br /> Development Technician <br /> D[pVPt N[KMSTA/NEILM�N/:SID 1 W"'ST SE COIUJ�01I <br />