Laserfiche WebLink
UBL/C WO/zKs <br />sasio 277 <br />October 13, 1994 <br />Page 2 <br />7. <br />8. <br />9. <br />]0. <br />11. <br />12. <br />13. <br />14. <br />15, <br />e <br />Hcarth's are r equired per manufactures listing. <br />A smoke dete�tor is required outside the sleeping rooms on the second floor of <br />the center units. <br />1'he main stair of the end units has a linen closet over the stair. 6'8" minimum <br />headroom is required. Please provide a section to verify headroom. <br />Master bath window sizes are not indicated. <br />Detail dimension on the secund floor end unit are missing. <br />A 22" x 30" attic access is required to each attic area. <br />The garage door header size is missing. <br />The 6'6" and 5'8" spans of the first floor 4 x 8 supports appear to be <br />oversuessed. Provide calculations. <br />Solid hlocking is required above the beam shown in detail S/A8, Section <br />2� 17(d)3. <br />In order for the processing of your application to continue, it will be necessary to <br />provide the Building Division with two complete new sets of drawings reflecting the <br />corrections requested. <br />Upon submittal of the drawings, your application will be given priority and plan :eview <br />will recommence. <br />Engineer/Building <br />}airM��n.���m <br />CITY OF EVERFTT • 3200 Ced2r Street • Everetl, WA 98201 •(206) 259-8800 • Fax (20fi) 259-8A56 <br />