3 Serun Fence - Any secunty fence er�cted oroun�l fhe cons;ruction site ;h.�ll b� lor,alcrl s�� :r: <br />!o not obstrucl any existmg hydranl, fire prolection eqwpment, or Fue Depariment ar,cess II <br />F �re Department acr.ess is obstructed, gales or other openings shall be provided for access <br />Premise ident�(icati�n - Prem�ses shall be clearly ide�ldied by the correct address at ihe slrret <br />entry. Buildings shall be ciearly idenlified so as to be vis�ble and Ieg�ble froin the access ro�d <br />Individual apartments and swles, whPre apphcable, shall be clearly and legibly ident�fied hurn <br />the access road. See EMC 16 03, Section 505 1 1 I�ddress Posting Pol�cyj <br />8-inch address numbers are required. <br />S Fire Hydran,s Lor,aUons as planned are ricr.r ;�' ibte <br />G Fire ilow for this project is 1,500 gpm <br />7 Porlable Fire Proleclion - A portablc fire ext�nyu�sher w�(h a min�mu n U L ratinc� of <br />2•A 10-B:C shall be provided within 75 feet of iravel on all floors of each bwldiny d,inn , <br />construction and prior lo occupancy <br />H Garaqes - Install a por'ablc fire exlinguisher wdh a minimum U L rating o( 2-A:40-E3 C.. ith�n i�l <br />teet travel distance of all portions of this building <br />9 Pire Alarm SVstem (NFPA 72) - An approved automatic (ue deteclion system shall be provid�zd <br />as required by City Ordinance No 3021-07, Chapter 1G 76, of the Everett Municipal Code <br />Plans (or such system sh^�I be subm�ited to the Fire Code Official for rev�ew and approval pnor <br />to instaltat�on. Submittal ;hall include cut sheets oi all equipment intended (or use Appropnale <br />tr�p lests, witnessed by a Fire Department Inspector, shall be per(ermed, along with ,� rertihcate <br />of comple6on, pnor to hnal acceptance of Ihe sys�em <br />Fire alarm systems shall be mslalled according to NFPA Ghapter 7� Installation of fire alarm <br />components, including basic wiring, may not commence before plans are approved by <br />the Fire Department Plan Reviewer. Fire atarm draw�ngs musl be professlon�liy rr:nderod. in <br />su(hr,u�nl detail, and musl be fnternally consistenL Riser diagrams must match installotion plans <br />,in�i load calr,ulations Componr.nls must be hsted and approved for us� �oyclher Chanq��s lu <br />pl,ins must include new drawings and calculations anA must be approved by the F�re <br />U���,arimenl Plan Reviewer prior to mstall�lion Fire alarm inslallalion is subjecl to field <br />ins��er,tion by a Fue Department Inspector. An approved set o( plans and Ihe [ngmeenng 8 <br />Puhhc Services Department eleclrical permd must be present for any installition inspeclioi� <br />��re alarm systems shall be installed undcr permit o( the City of Everett [nyineenng ft 1'ul�b� <br />SNrvices Deparimenl Electrical inspections and approval are requi�ed pnor to calfing 1„r <br />acc:eG,tance tests Call (4; 51 257-BE110 lor pennit inlonnaUon <br />Tlie absence of working phone lines for the alarm system will be cause (or postponing <br />Fire Department inspection and testing and shall result in denial of occupancy. <br />A co, y of NFPA 72 Rccord of Complelion form rnusl he hiled oul pr��r to I�nal ocrupnncy �NI f'A <br />72. �007 Fdition_ ��oge 7�-3'i) <br />