Laserfiche WebLink
. ' r ( <br /> PUBLIC WORKS FERMIT COMMENTS <br /> 4. As per Public Works approved plan deted <br /> 5. Connect side sewer per City Standard kti01. <br /> �onnect side sewer per City Standard M's 601, 602, 604. <br /> 7. Connect all rooftop downspouts to the side sewer. <br /> � Connect rooftop downspo��ts to the dreinage system provided }or thia lot. <br /> 9. Roofto^. runott must be discherged to a roof downspout infiltration system per Ciry of Everett <br /> Storm Manual 3-2.6.2 Width _, Depth __, Langth _. <br /> 10. The contr3ctor must meet with the Public Works InSpector to discuss potential drainage <br /> routing priar to beginning the project. <br /> 11. Install erosion control measures as determined by the Pub;ic Works inspe^tor, such as silt <br /> fence, straw bales, swales, or erosion blenkets. <br /> 12. nstall erosion co��trol measures per Ciry of Everett Standards for small parr.els <br /> 13. emove erosion conirol measurea upon compledon o?the project prior to tinal approvel of the <br /> - permit. <br /> (i4 II excavated materiel from foundation, sidewalk and driveways shall be heuled to an <br /> epproved, permitted site. Nc wasting of material is allowgd on this buflding lot. <br /> 15. Remove and replace curb, gutter and sidewelic as per Ciry of Everett Standard Plan #'s 305A <br /> & 308 on this proposei's frontage as dlrected by the Public Works Inspector(i.e. all �nused <br /> driveways and any broken or dameged area must be replaced). <br /> 16. Install a Type I ooncrete drivewey per Ciry of Everett Stendard #307. <br /> 17. Pave drivewey from the front property Ilne out to the street paving. <br /> 18. Contact t�ie _Water Dfstrict (or connecting provisions for this building's <br /> water and sewer services. <br /> 19. A catch basin as per City Standerd Plen k402 with a ges trep per Standard Plan M410 is <br /> required for the parking area. <br /> 20. If a sewer pump system �s to be �stalled, the pressure Iine muat discherge into a privete <br /> menhole, then gravity 11ow acros_ the public right-of-way. <br /> 21. A sprinkler system is requirec for this building in compiierce with ihe requiremonts of NFDA <br /> Standerds 13D. <br /> PWCcmments <br /> /G�v �n � l,s•- � <br />