My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2216 116TH ST SE 2016-01-01 MF Import
>
Address Records
>
116TH ST SE
>
2216
>
2216 116TH ST SE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2017 12:50:00 PM
Creation date
4/14/2017 9:11:18 PM
Metadata
Fields
Template:
Address Document
Street Name
116TH ST SE
Street Number
2216
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
83
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
___________________________________________________________________________ <br />fSUN 5.3 COMPONENT CHECKLIST 07/23/92 <br />.LE: A:\0592119.WS HOUSE ID: 05-92-119 <br />�____________________________________________'_______________=_-______________ <br />------------------ <br />Name: Floor Area: 1037 ft2 <br />Address: 2208 116th STREET SE Heating Type: Electri.c: 2oned <br />Reference: 1991 WA State Energy Code <br />---------------------------------------------------------------------------•----- <br />FRAMING INSPECTION <br />--------------------------------------------------------------------------- <br />Approved plans: <br />Are available onsite <br />Air leakage: <br />Soleplate is caulked or glued to subfloor. Rim joists between <br />stories are caulked/sealed. <br />All holes in building envelope (i.e. exterior ceilings, walls, and <br />floors) are caulked/sealed, including all electrical, plumbing, <br />ana }iVAC penetrations. <br />Outlets, switch boxes and recessed fixtures on exterior walls are <br />caulked/sealed with approved sealant, or have foam face gaskets <br />installed. <br />Anx recessed Lights ar� ZC rated, air tight, and sealed to the <br />ceiling sheetrock. <br />Wall frasing: <br />Net wall area: 998 ft2 <br />Advanced framinq with studs s�aced 24" o.c., R-l0 insulated <br />headers and no isolated cavities which cannot be insulaY.ed. <br />Structural panels: <br />All structural sheathing is stamped "Exposure I�', "Exterior", or <br />TECO tested-ANSI A20B.187 <br />Windows: 112.0 ft2) <br />(MILGARD VINYL W/ARGON 34.0 ft2) <br />(MILLGARD SGD VINYL 2GL W/ARGON <br />Windows are installed as shown on the approved plans. The rough <br />opening around windows and doors is caulked/sealed. <br />Exhaust fans, spot ventilation: <br />Bathroom fans are 50 CFM, water closets are 50 CFM, Laundry <br />facilitys are 50 CFM, kitchen fans are 100 CFM. Fan ducting has <br />minimal bends and terminates outside of the building. <br />The whole house exhaust fan is between 80 and 120 CFM. <br />The whole house fan is rated at 1.5 sones or less (unless remotely <br />located). <br />INSULATION INSPECTION <br />-------------------------------------------------------------------- <br />Wall insulation: 243.0 ft2) <br />(R19 ADV Lap Wood <br />g ___________________________________ <br />_____________________________________ Pa e 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.