My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1600 121ST ST SE 2016-01-01 MF Import
>
Address Records
>
121ST ST SE
>
1600
>
1600 121ST ST SE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2017 10:56:45 AM
Creation date
4/14/2017 10:16:29 PM
Metadata
Fields
Template:
Address Document
Street Name
121ST ST SE
Street Number
1600
Imported From Microfiche
Yes
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1894
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PUBL/C f�f/Ol�CS <br />� 4;.. <br />April 26, 1993 <br />Mr, Dick Bauslwd <br />Mithun Partners, Inc. <br />414 Olive Way, Suite 500 <br />Seattle, Washington 98101 <br />RE: Owner: Schneider Homes <br />Job Address: Not Assigned (south of Silver Lake) <br />Plan Check No: 39477 thru 39500 <br />Dear Mr. Bauskrud: <br />In response to your application for a construction permit, your pllns have been examined and you <br />are adviscd that the issuance of a permit is being withheld for :he reasons listed below. These <br />comments address building issues only, additional revisions or aciditions may be required by other <br />departments (such as Utilities, Planning or Fire). All references refer to the 1991 Uniform <br />Building Code, as amended by thc State of Washington and/or Washington State Energy Code <br />1991, 2nd Edition, unless stated otherwise. <br />�� 1. The following buildings may be of Type V N construcdon if desired: 9, 11, 16, I8, 19, 23 <br />and the Rec. Building. <br />i 2. The following buildings are not r qui ed o have an automatic fire suppression system (fire <br />sprinklers) if desired: 2;� ',�; �1.3f , 18, 19, 23 and the Rec. Building. Please verify <br />w�th the Fire Marshal's 6ffice prior to elction. <br />! 3. The buildings are mixed occupancy buildings as follows: <br />R1/M1 - Buildings 1 thru 17 and 20 thru 23 <br />R3/Ml - IIuildings 18 & 19 <br />A3/B2 - Rec Auildir,g <br />t 4. Buildings required to be of one hour rated constn�clion throughout must use two layers of 5/8 <br />inch Type 'X' G.W.B. for the finish ceiling of the roof/ceiling assembly. See Table 43-C <br />Item 21-1.1 and GA File No. RC 2601. <br />� 5. Buildings required to be of one hour rated <br />sheathing an the exterior if other than 3/4 <br />1.1 and UL Design No. U032. <br />construction throughout must use 5/8 inch gypsum <br />inch drop siding is used. See Table 43-II Item 17- <br />� 6. Units E& F inay use one layer of 5/8 inch Type'X' G.W.B. may bc used for the floor/ceiling <br />assembly scparating the basement garagc from the first floor. <br />CITY OF EVERETT� 3200 Cedar Street • Everelt, WA 98201 •(206) 259-8800 • Fax (206) 259-8856 �e`� <br />
The URL can be used to link to this page
Your browser does not support the video tag.