Laserfiche WebLink
v <br /> r <br /> PUBL/C f�f/O/�K5 'RM <br /> 891199) <br /> p <br /> PC 1345010 lhru 45027 <br /> January 13, 1995 <br /> Page 3 <br /> ✓13. The smoke detector shown outside the laundry room on the 2nd floor master <br /> rear plan sheet A3 should be relocated to the area above the stair landing. <br /> X14. The beams, columns and walls of the garage unit "KC" must be protected with <br /> one hour construction, sec. 503(b). <br /> Al 5. Unit spearation walls must be of one hour construction. Please call out the <br /> appropriate wall sections on each plan. sec. 1202(b) <br /> ✓16. A Floor or landing not more than 8" below the floor level is required at the entry <br /> door, garage door and patio door of all duplex dwelling units. Sec. 3304(i) <br /> exception B. <br /> V17. A 30" wide minimum space is required for the masts: bedroom toilet shown on <br /> the 2nd floor plan, master-front sheet A3, Sec. 511(a). <br /> 118. An attic access opening 22" x 30" minimum must be provided to each attic area <br /> (divdied by draftstops or walls) illustrate locations on floor or framing plans. <br /> Sec. 3205(x). <br /> +,�9. Provide dimensions for the storage unit shown on "2/2 ext" unit sheet A10. <br /> ✓20. Please clarify the deck dimensions and configurations shown on sheets A10, <br /> A10.1, A16, A17 and A18. <br /> v21. The windows between the master bedroom and rear deck units "2/2 int" must be <br /> 3/4 hour rated on buildings P & Q, Sec. 3306(k). <br /> j/ 2. The windows and doors between the living rooms and rear decks, units "2/2 int" <br /> must be 3/4 hour rated on building Q., Sec. 3305(g). <br /> ,q V25. Provide door specifications and jamb details for the accessible units (type A & <br /> B) to verify compliance with Sec. 31060)2. <br /> CITY OF EVERETT• 3200 Cedar Street • Everett, WA 98201 • (206) 2598800 • Fax (206) 2598856 <br />