Laserfiche WebLink
WATTSUN 5. 4 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 01/13/95 <br /> FILE: C: \\WATTSUN5\\BART668.WS HOUSE ID: <br /> Skylights ® 2G1 Vinyl 1/2" U-0.650 8.0 5 .2 <br /> Ceiling R38 blown Attic STD baffled U-0. 031 1174 36 .4 <br /> Infiltration Standard Air Sealing ACH-0.350 12680ft3 ( 81 .2) <br /> ---------------------------- <br /> Proposed UA 473 <br /> Struc Mass Light Frame, Sheetrock walls M- 3 . 000 1636 4908 <br /> ------------------------------------------------------------------------ -------- <br /> HEATING/COOLING/VENTILATING SYSTEMS <br /> PROPOSED <br /> Heating System Type: Gas Furnace <br /> Make: Contractor' s Spec <br /> Model : 001/ <br /> System Efficiency: 78 8 <br /> Modified Efficiency: 0 k <br /> Design ACH: 0.60 <br /> Design Load(at 44F dt) : 27539 Btu/hr <br /> Duct Losses (t Den Load) : 0 Btu/hr( 0%-) <br /> Total Load: 27539 Btu/hr <br /> System Size: 41500 Btu/hr (1501) <br /> Average Annual Heat: *** MBtu <br /> Annual Cost : $ *** <br /> Ventilation System: Integrated Spot <br /> & Whole House <br /> Cooling System: <br /> SEER: 0. 0 (Ducted) <br /> Coding Load(at 4F dt) : Btu/hr <br /> System Size ($Over) : tons (@125%) <br /> Annual Cool Requirement: *** kWh/yr <br /> Solar Access: Partially Shaded <br /> ---------------------------------------------------------- ---------------------- <br /> PROPOSED DUCT SYSTEM <br /> Location Avg Rvalue Surface Area <br /> --------------------------------------- ---------- <br /> SUPPLY Vented crawlspace R- 8 .0 150. 0 ft2 <br /> RETURN Attic or garage R- 8 . 0 52.0 ft2 <br /> -------------------------------------------------------------------------------- <br /> Page 2 <br />