Laserfiche WebLink
C, 0 <br /> 6. Guard in-fill components, balusters and panel fillers shall be designed to withstand a <br /> horizontally applied normal load of 50 pounds on an area equal to I square foot. <br /> 7. All glazing in railings regardless of area or height above a walking surface is by <br /> definition considered a hazardous location and is required to be snfety glass. <br /> Please prepare it response letter slowing where each item in this correction letter is <br /> addressed on the plan set. <br /> Upon resubmittal of the drawings, your application will be given priority and plan review will <br /> recommence. <br /> All required submittals shall be of'sullicient detail and contain sufficient information to ensure <br /> that the proposed structure will be constructed in compliance with all adopted codes. <br /> Sincerely, <br /> Jell'I Ieilnum <br /> Mvelopment Technician <br /> 425-257-8976 <br /> L'mail:jheilman n ci.cvcrctt.wa.us <br /> �.ai «vnw�wni�.�iu »'nsN� <br />