Laserfiche WebLink
This home has been professionally insulated with <br /> Owens-Corning <br /> Fiberglas <br /> Insulation <br /> To meet the stated thermal resistances(R-Values),the manufacturer provides the following specificatic',1s: <br /> Blanket Insulation Advanced ThermaCube Plus`" <br /> Blanket and ball insulation when Loose Fill Insulation 03MO4269 <br /> installed according to the Stated R-Value is provided by installing the required^umber of bags per 1,000 <br /> manufacturer's recommendations sq.ft.at a thickness not less than the label minimum thickness. nstallation of <br /> will provide the stated R-Value. the required number of bags may yield more than the specified minimum <br /> N Minimum thickness and minimum sq.N.weight.Failure by the installer to Provide both <br /> FI-Value Thickness the required bags and at least the minimum thickness will result i i lower <br /> insulation R-Value. <br /> ToObtainan Installed Specification For Open Blow Attics <br /> insulation insulation <br /> resistance should not Nominal not weight of Insulation per bag is 35 lbs. <br /> R of: be less than: <br /> R-38 12"Thick 13AGSPER MAXIMUM MINIMUM MINIMUM <br /> t R-30 9112"Thick RVALUE' 1000 SO FT NETCOVERAGE WEIGHTSO.FT. THICKNESS <br /> I R-22 63/4"Thick Tooblainan No.of bags per Contentsofthis Weight per sq.tl. Installed <br /> R-19 61/4"Thickt Insulatinn 1000sqrtof bag should not of Installed Insulation <br /> R-13 3%ft Thicktt resistance net area shall cover more than: Insulation should should not <br /> R-11 31/2"Thick Rol not be less than. not be less than: belessthan: <br /> tR-18 in a 5th"cavity R-49 1 26.3 38 Sq.Ft. 0.922 20112 In. <br /> ttR-12.7 in a 31/2"cavity R-44 23.3 43 Sq.Ft. 0.822 18112 In. <br /> R-38 20.0 50 Sq.Ft. 0.705 16 In. <br /> R-30 15.6 64 Sq.Ft. 0.550 123/4 In. <br /> R-26 13.b 74 Sq.Ft. 0.474 11 In. <br /> R-22 11.4 88 Sq.Ft. 0.399 91/2 In, <br /> R-19 9.8 102 Sq.Fl. 0.343 81/4 In. <br /> R-11 5.6 178 Sq.Ft. 0.197 43/4 In. <br /> R means resistance to heat flow.The higher the R-value,the greater the Insulating power. <br /> The following products have been installed as t$ecified above: <br /> 7%t—I aU�t C v <br /> LL:GGItir a'1a04' coverage <br /> Type(chock appropriate box) R-valuo thickness no pkgs. area <br /> krah unlaced fail FS-25 loomfill <br /> Ceilings ❑ ❑ ❑ ❑ 0; .30 13 r At I xWo � <br /> Floors ❑ ❑ ❑ ❑ l4 (p /03x'0 <br /> ❑ ❑ ❑ ❑ <br /> Walls ❑ ❑ ❑ ❑ 19 (o a <br /> ❑ ❑ ❑ ❑ <br /> Installedby�.A /fi ,y04Qi <br /> d4llf4-tlil444 Builder: <br /> C)6I �1;11 4j— 9/" yl l <br /> signal a date signature date <br /> OWENS-CORNING FIBERGLAS CORP. <br /> c"Prwhl 111117 o".nacmm"11 FiNr111n CaP Insulation Operating Division <br /> P"e eP 111 aw,4sxo Pnm"e m us A.wm N, 11187 Fibergtas Tower,Toledo,Ohio 43659 <br />