My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
306 61ST ST SE 2016-01-01 MF Import
>
Address Records
>
61ST ST SE
>
306
>
306 61ST ST SE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2017 8:42:41 PM
Creation date
4/17/2017 8:42:22 PM
Metadata
Fields
Template:
Address Document
Street Name
61ST ST SE
Street Number
306
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
125
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
8/172007 City of Everett Page I <br /> I1:05:00AM <br /> INSPECTION ACTIVITY REPORT <br /> Permit No. C0607-023 Site Address 6103 BEVERLY LN <br /> Applied 7/212006 Applicant I'ol <br /> Approved 8242006 Owner POHLAND TODD k HOLLY Block <br /> Issued 102/2006 Contractor POI BAND PAFN17NO k CONfKAL11N Tract <br /> parent Permit Description NEW DUPLEXUnit 2 addteesed306.61st St SE <br /> Notes DUPLEX FACES 2 STREETS-SECOND ADDRESS:306.61 ST ST SE <br /> Scheduled Completed Tvne Insnector Result Remarks Insneclor's Comments <br /> 10/122006 10/12/2006 Footing BUDDEN Approval As note-submit <br /> revised site plan <br /> 10/122006 10/122oob UFER Ground BUDDEN Approval <br /> 10/182006 10/18200' Foundation BUDDEN PtAppr-Con Req Submit <br /> mvisions/wall less <br /> storage arca <br /> 10252006 10252006 Foundation BUDDEN Approval Storage areas <br /> 10252006 1025200[ Fooling BUDDEN Approval <br /> 1026/2006 1026/2006 Fooling BUDDEN Approval Stem walls <br /> 1122006 1122006 Under m I.CI'. PartislAppmval See notes 1.No clear place to leave this inspection <br /> report on site-no copy left <br /> 2.Pressure treated posts required in <br /> underfloor are+ <br /> 3.Pmitive connections required bet%= <br /> underfloor pmts and concKte piers <br /> 4.Couldn't find plans on site <br /> 11192006 11192006 Underfloor BUDDEN Approval <br /> 1242007 1242007 ShearNailing III IDDEN Approval See notes 1)Comp:cte post/beam connectors at <br /> porches <br /> 2)Nail off loose panels <br /> 3)Neil off hold down straps as necessary <br /> 4)Complete sill hardware. <br /> 5)Strap muneupted platchnes. <br /> 6)Nail off truss hangers. <br /> 7)Note one hour conditions at grange k <br /> storage areas <br /> 1262007 12612007 Framing BUDDEN Approval <br /> 12612007 1262007 MechRougldn PONS PartialApproval See notes I --Mechanical rough OK except: I) <br /> Reattached exhaust in master hath;2) <br /> Complete:nsulation in crawl <br /> 2—Recall inspection for fireplace. <br /> 1262007 126/2007 PlbgRoughln PONS Approval See notes 1)Test on waste k water is down,left <br /> affidavit to sign and velum to inspector. <br /> Methods and materials OK excpct secure <br /> tub spouts,loose tub spouts will not be <br /> talented it Final <br /> 1262007 1262007 SheuNuling BUDDEN Cort Reqd Sec not" Provide revised/approved site plan as <br /> requested. <br /> 1292007 1/292007 ShemNailing nUDDFN Approval See notes Approval as noted Complete l-hour <br /> condition at storage room attic as discussed. <br /> 1292007 1292007 Framing BUDDEN Approval <br /> 2112007 2/12007 MechRoughln PONS Approval Mech rough <br /> complete <br /> 2/12007 2/12007 Wiping PONS Approval Gas at 15 PSI,OK <br /> for service <br /> 2/12007 2112007 InsulBldg BUDDEN Approval <br /> 2/12/2007 2/122007 IkywalMailing BUDDEN Approval <br /> INSP12 <br />
The URL can be used to link to this page
Your browser does not support the video tag.