My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1321 63RD ST SE 2018-01-02 MF Import
>
Address Records
>
63RD ST SE
>
1321
>
1321 63RD ST SE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/21/2021 7:47:47 AM
Creation date
4/17/2017 9:32:32 PM
Metadata
Fields
Template:
Address Document
Street Name
63RD ST SE
Street Number
1321
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
COMPLIANCE <br />REOUIRED V <br />INSPECTION I IMPORTANT: DO NOT place checks In the two left columns. <br />APPROVED <br />p lZf ED Exposed foam Insulation shall comply as follows (S. 502.1.4.7): <br />❑ Protected with metal or plastic flashing, or other suitable material that extends below grade. <br />❑ Insulation Is approved for sub -grade, exterior use and properly Installed. <br />p QAlrilow between fresh air ports and the wholo-house fan ensured by undercut doors/grills(VIAO,S. 302.6.4) <br />O ®Loosellll Insulation OK if (S.502.1.4.5): <br />❑ maximum ceiling slope not > 3 In 12 <br />❑> 30" o1 clear distance from top of bottom chord to underside of roof sheathing at the roof ridge. <br />p 6 mll black polyethylene ground cover, shall be lapped 12" at Joints and extend to foundation wall <br />ED ae Clearances shall meet listed minimums between Insulation and (S.502.1.4.3): <br />❑ chimney ❑Non -IC rated recessed lights: 1/2" to combustables, 3" to insulation. <br />O r U hatch shall be Insulated to required ceiling R-value and is weatherslripped (S.502.1.4.4) <br />O Attic access shall have wood dam or equivalent to retain loose fill Insulation in attic(S. 502.1.4.4) <br />O PAII exterior doors (except 20 minute doors) shall be weatherstripped (S. 502.4.3). <br />O Service hot & cold water piping In unoonditloned spaces shall be Insulated to R-3(S. 503.11) <br />CZ] r Service recirculation hot water piping In unconditioned spaces shall be insulated to Table 5.12 levels. <br />O [3 Qz Heat pump thermostat shall have progamable capability (S. 503.8.3.5) <br />O O V2s hemostat provided for each HVAC system with range of 55-75' F.(heating) (S.503.8.1.1). <br />O O �j eacilly accessible, automatic or Manual means provided to restrict or shut-off Heating input to each <br />zone or floor during periods not requiring heat (S. 503.8.3.1). <br />p q VrOntrols for hacktrp heat prohibit simillaneous operation of the primary system (S. 503.2.2(3)). <br />p e echanical ventilation system shall nave proper timers, andior switches (VIAO, S. 302.3). <br />Y-WCl z mechanical ventilation ducts shall have R-4 Insulation in uncondifionrid spaces (VIAO, S. 302.5) <br />p a echanlcal ventilation supply ducts in conditionened spaces shall havo R-4 insulation (VIAO, 302.5) <br />O O B upply ducts shall have volume dampers, or the equivalent, to balance system (S. 503.6). <br />p p upply and return air ducts shall have sealed dud Joints in unconditioned spaces (S. 503.10.2). <br />13 i VAC plenums, supply, and return air ducts shall have R-8 Insulation (Table 5-11, All options) <br />z lectrlc water heaters) shall have (S. 504.2.1. 504.3, 504.4) : <br />❑ separate power . shut-off ❑ 1987 NAECA Lable on tank <br />❑ noncompiessible R10 pad (unheated spaces only) ❑ Temperature setting s 120 F. <br />ED O s' howers and lavatories shall limit flow to s 3.0 gallonsiminute (S. 504.8.1). <br />p p owlmming pools(S. 504.5) shall have: <br />❑ readily accessible ON/OFF switch (pump, heater) ❑Pool cover ❑Piping Insulated to S. 503.11 <br />E3 O `411 fireplaces (VIAO, S. 402.3) shall have: <br />❑ 6 square inch combustion air supplyduct w/ accessible damper directly connected to the lire box <br />❑ Tight fitting glass or metal doors. ❑ Tight fitting flue damper <br />O O e Solid fuel burning appllance(s) (VIAO, S. 402.2) shall have: <br />❑Tight fitting glass or metal doors <br />❑Outside combustion air source directly connected to the fire box <br />❑ Exception: Non -direct, 4" diameter, dampered, combustion air source: allowed only for (1) new stove <br />installations in existing homes where obstruct ionsprecludas direct combustion air, or (2) Certral <br />heating systems located in unhealed spaces. <br />p 73 Three month, etched track radon monitor, printed Instructions, and Information sheets shall be supplied <br />to the single family dwelling or first floor units of multi -family dwellings by the general contractor (VIAO,S. <br />502.2.1), <br />WSEC Final pha5 '�bq rements: <br />Inspected by II Date <br />Page 6 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.