Laserfiche WebLink
COMPLIANCE <br />REQUIRED V <br />M <br />0 <br />0 <br />INSPECTION IMPORTANT: QQ�iQI place checks in the two left columns. <br />APPROVED <br />❑ Exposed foam Insulation shall comply as follows (S. 502.1.4.7): <br />❑ Protected with metal or plastic flashing, or other suitable material that extends below grade. <br />❑ Insulation is approved for sub -grade, exterior use and properly Installed. <br />❑ (DAlrflow between fresh air ports and the whole -house fan ensured by undercut doors/grills(VIAQ,S. 302.6.4) <br />❑ ©° Loosefill Insulation OK if (S.502.1.4.5): <br />❑ maximum ceiling slope not > 3 in 12 <br />❑ a 30" of clear distance from top of bottom chord to underside of roof sheathing at the roof ridge. <br />❑ g6 mil black polyethylene ground cover, shall be lapped 12" at Joints and extend to foundation wall <br />[3 Clearances shall meet listed minimums between insulation and (S.502.1.4.3): <br />❑ chimney ❑ Non -IC rated recessed lights: 1/2" to combuslables, 3" to Insulatior. <br />❑ hatch shall be Insulated to required calling R-value and is weatherstripped (S.502.1.4.4) <br />❑lAttic <br />Attic access shall have wood dam or equivalent to retain loose fill Insulation in attic(S. 502.1.4.4) <br />❑ All exterior doors (except 20 minute doors) shall be weatherstripped (S. 502.4.3). <br />Service hot & cold water piping In unconditioned spaces shall be Insulated to R-3(S. 503.11) <br />❑ Service recirculation hot water piping in unconditioned spaces shall be Insulated to Table 5-12 levels. <br />❑ QQ2 Heat pump thermostat shall have progamabfe capability, (S. 503.8.3.5) <br />❑ pa]Thermostat provided for each HVAC system with range of 55-75' R(heating) (S.503.8.1,1). <br />❑ Reacilly accessible, automatic or Manual means provided to restrict or shut-o" Heating Input to each <br />zone or floor during periods not requiring heat (S. 503.8.3.1). <br />❑ 11upply <br />ontrols for backup heat prohibit similtaneous operation of the primary system (S. 503.2.2(3)). <br />❑ echanical ventilation system shall have proper timers, and/or switches (VIAQ, S. 302.3). <br />❑ echanlcal ventilation ducts shall have R-4 Insulation in iinc r _onditloned spaces (VIAQ, S. 302.5) <br />Elechanical ventilation supply ducts in condillanod spaces shall have R-4 insulation (%IAO, 302.5) <br />❑ ducts shall have volume dampers, or the equivalent, to balance system (S. 503.6). <br />❑ o upply end return air ducts shall have sealed duct Joints in unconditioned spaces (S. 503.10.2). <br />❑ 1 VAC plenums, supply, and return air ducts shall have R-8 insulation (Table 5-11, All options) <br />❑ z lectrlc water heater(s) shall have (S. 504.2.1, 504.3, 504.4) : <br />0 separate power shut-off ❑ 1987 NAECA Lable on tank <br />❑ noncompressible R10 pad (unheated spaces only) ❑ Temperature setting s 120 F. <br />❑ showers and lavatories shall omit flow to s 3.0 gallons/minute (S. 504.8.1). <br />❑ ®Swimming pools(S. 504.5) shall have: <br />❑ readily accessible ON/OFF switch (pump, heater) ❑Pool cover ❑Piping insulated to S. 503.11 <br />❑ QAII fireplaces (VIAQ, S. 402.3) shall have: <br />❑ 6 square inch combustion air supplyduct w/ accessible damper directly connected to the fire box <br />❑ Tight fitting glass or metal doors. ❑ Tight filling flue damper <br />❑ e Solld fuel burning applience(s) (VIAO, S. 402.2) shall have: <br />❑Tight fitting glass or metal doors <br />❑ Outside combustion air source directly connected to the fire box <br />❑ Exception: Non -direct, 4" diameter, tampered, combustion air source: allowed only for (1) new stove <br />installations in existing homes where obstructionsprecludes direct combustion air, or (2) Central <br />healing systems located in unheated spaces. <br />❑PThree month, etched track radon monitor, printed Instructions, and Information sheet; shall be supplied <br />to the single family dwelling or first floor units of multi -family dwellings by the general contractor (VIAQ,S. <br />502.2.1), <br />Page 6 of 6 <br />WSEC Final phase requirements: <br />Inspected by: Date —� <br />