._1 <br />April 23, 19% <br />Rob and Deb Haines <br />1324 - 74th Street <br />Everett, WA 98203 <br />RC: Owner: Rot and Deb Haines <br />Jot. Address: 1324 - 74th Street <br />Plan Check hb: 90/24298 <br />Dear Mr. and F'as. Haines: <br />In response to your application for a construction permit, your plans have <br />been examined and you are advised that the issuance of a permit is bring <br />withheld for the reasons listed below: <br />1. 6 x 12 bean 0 unfinished basement is overstressed. <br />-'2. Inc: support indicated for existing roof where exterior wall is to tw- <br />removed. <br />3. No information on deck cixnstruction provided. <br />4. Guardrails shall have intermediate rails or ornamental patterns such <br />that a sphere 6 inches in diameter cannot pass through. <br />5. R-36 insulation required in attic space provide min 1" air apace s <br />sht+llow env of trusses. <br />6. Footings shall rest on undisturbed soil, a minimum of le" below grade. <br />Stem wall shall extend a minimaim of 6" atove finished grade. <br />7. Slabs within 12" of finisheo grade shall have a minimum of 24" of <br />R-IC rigid insulation at the perimeter. <br />In order for the processing of ycur application to continue, it will be <br />necessary to provide the Building Department with two new sets of drawings <br />reflecting the corrections requested. <br />