Climate Zone <br />5 and Marine 4 <br />6 <br />TABLE R402.1.1 INSULATION REQUIREMENTS BY COMPONENT <br />For SI: 1 foot .= 304.8 mm, ci .= continuous insulation, int .= intermediate framing. <br />• (a) R-values are minimums. LIfactors and SHGC are maximums. When insulation is installed in a <br />cavity which is less than the label or design thickness of the insulation, the compressed R-value of <br />the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. <br />• (b) The fenestration llfactor column excludes skylights. The SHGC column applies to all glazed <br />fenestration. Exception: Skylights may be excluded from glazed fenestration SHGC requirements in <br />Climate Zones 1 through 3 where the SHGC for such skylights does not exceed 0.30. <br />• (c) "10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the <br />continuous insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break <br />between the slab and the basement wall at the interior of the basement wall. "10/15/21.+TB" shall be <br />permitted to be met with R-13 cavity insulation on the interior of the basement wall p!us R-5 <br />continuous insulation on the interior or exterior of the wall. "10/13" means R-10 continuous insulation <br />on the interior or exterior of the home or R-13 cavity insulation at the interior of the basement wall. <br />"TB" means thermal break between floor slab and basement well. <br />• (d) R-10 continuous insulation is required under heated slab on grade floors, See R402.2.9.1. <br />• (e) There are no SHGC requirements in the Marine Zone. <br />• (f) Basement wall insulation is not required in warm -humid locations as defined by Figure R301.1 and <br />Table R301.1. <br />• (g) Reserved. <br />• (h) First value is cavity insulation, second is continuous insulation or insulated siding, so "13.+5" <br />means R-13 cavity insulation plus R-5 continuous insulation or insulated siding. If structural <br />sheathing covers 40 percent or less of the exterior, continuous insulation R-value shall be permitted <br />to be reduced by no more than R-3 in the locations Mere structural sheathing is used to maintain a <br />consistent total sheathing thickness. <br />• (i) The second R-value applies when more than half the insulation is on the interior of the mass wall. <br />• 0) For single rafter- or joist -vaulted ceilings, the insulation may be reduced to R-38. <br />• (k) Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated <br />with a minimum of R-10 insulation. <br />• (1) Log and solid timber walls with a minimum average thickness of 3.5 inches are exempt from this <br />insulation requirement. <br />