My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
423 75TH ST SE 2018-01-02 MF Import
>
Address Records
>
75TH ST SE
>
423
>
423 75TH ST SE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2021 4:23:42 PM
Creation date
4/18/2017 12:11:54 AM
Metadata
Fields
Template:
Address Document
Street Name
75TH ST SE
Street Number
423
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
277
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
49. 1A One•Ilour Fire•ftet stive Occupancy Separation <br />Is required between the boiler or central heat• <br />Ing plant and the rest of the building. Section <br />808. <br />Group D <br />49. <br />Group U, Division I Occupancies should he of <br />Type 1 or II construction unless complying with <br />the Cxceplion in Section 902 (b). <br />50, <br />Group D, Division 2 (3) Occupancies should be <br />of ono -hour fire -resistive construction. Table <br />No. S.C. <br />51. <br />Light and ventilation should comply with Section <br />905. <br />52. <br />A One Hour Fire -Resistive Occupancv Separation <br />Is required between ilia boiler or central heat. <br />Ing plant and the rest of the building. Section <br />908. <br />$3. <br />Exterior openings for rooms containing a boiler <br />or central heating plant should W protected <br />with three -fourths -hour fire -resistive assemblies <br />that are fixed, automatic, or self -closing if <br />located below openings in another story or if <br />less than 10 feel from other doors or windows <br />In the same building. Section 903. <br />Group F <br />St. <br />vehicle service stations should be of non• <br />combustible fire -retardant treated wood or one. <br />1Motor <br />hour fire -resistive construction. Section 1102 <br />(b). <br />55. <br />StoraCe areas in excess of 1000 square feet in <br />connection with wholesale or retail sales should <br />be separated from the public areas by a One. <br />Hour fire -Resistive Occupancy Separation un- <br />less the building is equipped throughout with <br />an automatic fire -extinguishing system. Section <br />1102 (b). <br />56. <br />LICht and ventilation should comply with Section <br />1)05. <br />57. <br />Exhaust ventilation at or near floor level is ro• <br />qutied by Section 1105. ' <br />53. <br />A One Hour Fire -Resistive Occupancy Separation <br />Is required between a boiler room or central <br />heating plant and the rest of the building. Sec. <br />tion 1108. <br />Group H <br />59. IA Group H Occupancy more than two stories in <br />height or having more than 3000 square fact <br />above the first story should be of one hour <br />fire -resistive construction lhruuchout. Section <br />)302 (b). <br />60. IThe following rooms should have window areas <br />as specified in Section 1305 (a), one-half of <br />which is openable. <br />Cl. Mechanical ventilating system in ballrooms <br />should provide five air changes per hour di• <br />really to the outside. Section 1305 (a). <br />62. Windows from ....................................... should <br />not be ron"dcrcd ,,s furiwton^ requited 1•r:hl <br />e'r ventilation since they do nil ores to a yard, <br />entrt, or street in accordance with Section <br />1305 (,1). <br />63. Coutls botmded on four sides with walls should <br />be nt lust 10 feel ul Icul:lh. Fa' mutt•, o"ore <br />than two slums to lu•q•hl, the tequu„I !u+ <br />should he incleaw,$ by euc fool arol t1 1, <br />quucd I, nCih lv 2 Icel for each add,uunal <br />story.:krhnn 1306 (c). <br />64. <br />Every sleeping room below the fourth floor <br />Should have at lead one window or exterior <br />door approved for emergency cxrt or rescue. <br />Section 1304. <br />65. <br />.......................................i................ room should <br />have the Inlninmm celing height required in <br />Section 1307 (a). <br />66. <br />........................................................ room should <br />have a minimum superficial floor area of <br />.................... square feet. Section 1307 (b). <br />67. <br />Efficiency dwelling units should comply with <br />Section 1308. <br />68. <br />A One -Hour rire-Resislive Occupancy Separation <br />Is required between a boiler room or central <br />beating plant and the rest of the building. <br />Section 1312. <br />69. <br />Every dwelling unit and guest room should have <br />comfort heating facilities as specified in Sec. <br />Von 1311. <br />Group J <br />70. <br />Group J Division 1 Occupancies are limited to <br />1000 (3000) square feet in floor area and one <br />-story in height. Section 1502. <br />71. <br />Garages should not open direN.ty into a room <br />used for sleeping purposes. Section I504. <br />72. <br />An approved noncombustible material or asphal• <br />tic paving material is required for garage floor <br />surfaces. Section 1504. <br />EXIT REQUIREMENTS <br />73. <br />An occupant load sign is required in classrooms, <br />assembly areas, etc., having an occupant IoaJ <br />of more than 50. Section 3301 W. Sec ............ <br />..................... _...... ............................................ <br />74. <br />Conforming exits arc required from the r,rcas <br />below os specified in Section 3302 (a). <br />:.................... :............... <br />... _........ _................. <br />[i l..l........... ................................................. ...... <br />75. <br />Exits should have a minimum senarat,on of one. <br />hair Ilia maximum overall , a ronal of file build• <br />Ing or area served. Section 3-402 (c).............. <br />76. <br />lie ppoint in the buildinn should be more than <br />l50 (200) fact from an ewterior exit, horizontal <br />exit, enclosed stairvroy, or exit passaCeway, <br />measured in the direction of travel. Section <br />3302 (d)........................................................... <br />77. <br />Exit door should' swing. In the direction of <br />egress. Section 3303 (L•). See doors ................. <br />78. <br />Double acting doors are not allowed whom crrv� <br />fag a tributary occupant load of more than 100. <br />Section 3303 (II). <br />79. <br />Exit doors should be openable from the inside <br />without the use of n key, special hnovd•,dge, or <br />effort. Section 3303 (c). Note also that flush <br />bolls or surface- bolts are prohibited. <br />80. <br />Exit doors slrnuld he a minimum sue or 3' x 6V <br />, <br />with a minimum hoer wring. el 90 denreCS. <br />Section 3303(it) ............................................... <br />_-_ <br />11% <br />the flrl Il lllle/I5,(1n (cl_ear wntth) at dn,liw]S5 <br />should he Imed tit delarnunlnr cxd widths <br />lequiled by SoLliml 3.107 (b). :;vrhon 33rq <br />((1). In ron;idet;Itinn of door tluc Anease%, pear: <br />lardwaln, dent `.wilily I'Ic.. Me rrquded ,oil <br />wit)llis have not been hllln:hrd. Gne tutu <br />
The URL can be used to link to this page
Your browser does not support the video tag.