16. • <br />Exterior (court) walls within .................... feet of <br />lines should be of ...............: hour construction. <br />Section .................... 03 (a). <br />17. <br />OpenmCs in exterior (rotirl) walls within .......... <br />feel of property Imes should be protected with <br />lhree•foutlhs•hour lire assemblies. Section <br />• <br />.................... 03 (b). <br />IS. <br />Usable space tinder the first floor except In <br />Group I (J)Occupancies should be enclosed <br />as requirei d n Section 1703. <br />19. <br />construction for structural frarne <br />elements in the exterior walls should comply <br />1F.te-resistive <br />With Footnote No. 1 or Table No. 17•A and <br />Section ........................ See Section 1702 for <br />Clarification. <br />20. <br />SuiWinC paper should be applied to exterior <br />wails as sped ed in Section 1707 (a). <br />21. <br />for floor openings should comply <br />IEnclosures <br />with Table No. 17•A, Section 1706. Details <br />should clearly indicate this. <br />22. <br />Structural members carrying masonry or can- <br />Clele walls in buddincs over one story in hciCht <br />should be protected with minimum one -hour <br />file protection. Section 1708. <br />23. <br />Nonabsorbent finish and backing for toilet room ' <br />walls and floor should conform with Section <br />' <br />1711 (a). <br />24. <br />Shower stall walls should be finished with a <br />hard, nonabsorbent surface to a hciCht of 6 <br />feet. Section 1711 (b). <br />25. <br />Doors and panels of shower and bathtub An. <br />closure should comply with Section 1711 (e) <br />to (C)• <br />26. <br />'Parapet walls not less than ................ inches In <br />• <br />I hciCht are required. Section 1703. <br />27. <br />overhangs and similar architectural pro• <br />lEavor <br />)ectons should comply with Section 1710. ' <br />28, <br />Projections beyond the exterior wall should con- <br />form with the least restrictive of the following: <br />(a) A point one-third the distance to the proper• <br />• <br />line from an exterior wa8. Section 504 <br />( ). <br />(b) A point one-third the distance from an as• <br />sumed vertical plane located where fire - <br />resistive protection of openirn,,s is first re- <br />quired due to location or property. Section <br />604 (b). <br />29. <br />Envelope ceilings should satisfy the following <br />conditions (Section 43(13 (b) 6.1: <br />'(a) Should not tie used to provhle fire protect- <br />lion beam and enders supporting more than <br />one floor. <br />(b) Columns should be Individually fire pro. <br />tooled.' <br />(e) Duct and outlet openings are limited to 100 <br />square inches nl each 100 square feel of <br />ceiling area and should be protected with <br />approved fit(- (I. nlpem. <br />(d) Llecllic l court boxes should be of steel <br />and not plcater than 16 square inches in <br />1- <br />-_ <br />30. <br />_area. <br />board tollors in conjunction with rue• <br />Ir SISh\'1• asS"n111h PS 6hUlllli 11• wJJ.J!Jllyd at <br />JGppsnm <br />Inielvah. lint "Reeling 1G inl'lles. Item 27, <br />Table No: 43-C. <br />ill. <br />Wood stripping. or suspended wood systems for <br />gypsum board ecihnCs should bo not less I1,311 <br />2-inch nominal thickness. Section 470•1 (ti). - <br />(Section 4703 (b) for wait stuppmg•1 <br />32. <br />Float partition layout, and deteils should be s'.Ib- <br />mitted prior to installation to justify com;:h• <br />ance with occupancy, fhre•reslstive, structural, <br />find exit requirements. <br />33. <br />Justifying test data in conformance with Seclicn <br />106 or an IC00 research recommendation is <br />requiredfor ....................................................... <br />34. <br />Rooms in whirh rubbish (linen) chutes telmit)tC <br />should be separated from the remainder of the <br />building with a one -hour occupancy separation. <br />Seel m 1706 (e). <br />35. <br />Openings Into rubbish and linen chutes should <br />not be located in required exit corridors or <br />stairways. Section 1706 (c). <br />SPECIAL OCCUPANCY REQUIREMUITS <br />Group U <br />36. <br />U•3 Occupancies should be of Ono hour lire- <br />lstive <br />a()gntorabovconstruction <br />))� <br />thefirststory. Sectcated ion <br />37. <br />U•2 Occupancies with an occupant Ic3d of IC-0 <br />or more should be In Type I. II, III one-ttour. III <br />Ifeavy Timber or IV one -hour buildir.Fs. The <br />assembly room should not be in a basement <br />it it contains this high occupant load. Section <br />702 (b). <br />38.. <br />The main entrance should front directly upon or <br />have*a 20-loot wide access to a public way al <br />least 20 feet in width. Section 703. <br />39. <br />Lirlit. and ventilation should comply with Section <br />705. <br />40. <br />A One -Hour rife -Resistive Occupancy Separalien <br />is to lied between the boiler or central heat. <br />In plant and the rest of the building. Section <br />708. <br />41. <br />Exterior openings for rooms containing a boiler <br />or central heating plant should be protected <br />will, lhrce-fourths•hour fire -resistive Mehl' lies <br />that are fixed, automatic, or sclf-closi"C d to• <br />Baled below openings in another story or if Icss <br />than 10 feet from other doors or windows in <br />the some building. Section 703. <br />Group C <br />42. <br />Atmospheric separations should comply With <br />Section P02 (b). <br />' <br />43. <br />Use of rooms shnuld be, clarified. Note )hot <br />rooms In Divisions I and 2 Oeeupart used <br />for day care purposes land rooms used for <br />gmdo pupils and <br />kindurCarten, for-.6 or second <br />Division 3 Occupancies cannot be located <br />above the first story. Section 1102 (c). <br />44. <br />eseparated <br />Sogrtrl <br />portions" of Ihasbuildinbytint less plan <br />a Onedfogr lirc.licslstiva 0ccup311cy acpala• <br />Iron. Section 801 (d). _ <br />45. <br />or <br />One required e4rt t.hould front directlyII <br />cnvdn. <br />have n 20runtW. Ida access to. . I". Y • <br />Ieasl 20 fret in width. Section 8O3 (a). <br />46. <br />Sanitary laulhtm should be provided in accord•- <br />ancc Willi serlion 1105, <br />47. <br />1 icld Imo vcnhlatu•11 should comply \will hccbon <br />