My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
615 75TH ST SE 2018-01-02 MF Import
>
Address Records
>
75TH ST SE
>
615
>
615 75TH ST SE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2021 4:47:30 PM
Creation date
4/18/2017 12:19:54 AM
Metadata
Fields
Template:
Address Document
Street Name
75TH ST SE
Street Number
615
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
180
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
16.' <br />Exterior (court) walls within .................... feet of <br />lines should be of ...............: hour construction. <br />Section .................... 03 (a). <br />17. <br />Openings in exterior (court) walls within ............ <br />feet of properly Imes should be protected with <br />three -fourths -hour lire assemblies. Section <br />• <br />.................... 03 (b). <br />18. <br />Usable space under the first Iloor except In <br />Group I (J) Occupancies should be enclosed <br />as required in Section 1703. <br />19. <br />construction for structural frame <br />elements in the exterior walls should comply <br />Irire-resistive <br />with Footnote No. 1 of Table No. 17-A and <br />Section ......................... See Section 1702 for <br />clarification. <br />20. <br />8uildine paper should be applied to exterior <br />walls as specified in Section 1707 (a). <br />21. <br />Enclosures for floor openings should comply <br />with Table No. 17•A, Section 1706. Details <br />should clearly indicate this. <br />22. <br />Structural members carrying masonry or con - <br />crate walls in buddings over one story in height <br />should be protected with minimum one -hour <br />fire protection. Section 1708. <br />23. <br />Nona bsorbent finish and backing for toilet room ' <br />malls and floor should conform with Section <br />1711 (a). <br />24. <br />Shower stall walls should be finished with a <br />hard, nonabsorbent surface to a height of 6 <br />feet. Section 1711 (b). <br />25. <br />Doors and panels of shower and bathtub en• <br />closure should comply with Section 1711 (e) <br />to W. <br />26. <br />Parapet walls not less than ................ Inches In <br />• <br />I height are required. Section 1709. <br />27. <br />overhangs and similar architectural pro. <br />' <br />JEave <br />Jections should comply with Section 1710. ' <br />28. <br />Projections beyond the exterior wall should con• <br />form with the least restrictive of the following: <br />(a) A paint one-third the distance to the proper• <br />ty line from an exterior wall. Section 504 <br />(b). <br />(b) A point one-third the distance from an as. <br />sumed vertical plano located whore fire• <br />resistive protection of openings is first to. <br />q fired duo to location of property. Section <br />b04 (b). <br />29. <br />Envelope ceilings should satisfy the following <br />conditions (Section 4303 (b) 6.1: <br />(a) Should not be used to provide fire protee• <br />Ilion beam and Cadets supporting more than <br />one floor. <br />(b) Colunos should be Individually fire pro. <br />looted. <br />(e) Duct and outlet openings are limited to 100 <br />square inches in each 100 smlale fret of <br />ceiling area and should be pmlected with <br />applatled fire 11.1mpers, <br />(d) I.lectrical nutlet boxes sfmuld be of %loci <br />find not greater than 16 squate inches in <br />area. <br />30. <br />board ceilmgs in conjunction with fire. <br />Irb:UYe Ac%elldrlie% Should be wipporied at <br />110.),1151111, <br />inl.eivals not exceeding 16 Inches. Item 27, <br />table No; 43•C. <br />dl. <br />Wood stripping or sespended wood systems for <br />gypsurn board crilnu;s should he not less than <br />2-inch nominal thickness. Section 470 (b). . <br />(Section 4703 (b) for wall shipping.% <br />32. <br />f"inal partition layouts and det.+us should be suh- <br />milted prior to installation to justify comply <br />a nce with occupancy, hre•resislMC, structural, <br />and exit requirements. <br />33. <br />Justifying test data in conformance with Section <br />10G or an ICOO research reconnnendaticn is <br />requiredfor ....................................................... <br />34. <br />Noorns in which rubbish (linen) chutes termirnle <br />should be separated from the remainder of the <br />building with a one -hour occupancy separation. <br />Section 17C6 (c). <br />35. <br />Openings into rubbish and linen chutes should <br />not be located in required exit corridors or <br />stairways. Section 1706 (c). <br />SPECIAL OCCUPANCY REQUIREMENTS <br />Group D <br />3G. <br />0.3 Occupancies should be of one -hour fire. <br />resistive construction if located in a basement <br />or above.the first story. Section 702 (b). <br />37. <br />0.2 Occupancies with an occupant load of 1C00 <br />or more should be in Type I, 11, III one -hour. III <br />licavy Timber or IV ono-F.ur buildings. The <br />assembly room should not bo in a basement <br />If it contains this high occupant load. Section <br />702 (b). <br />38.. <br />The main entrance should front directly upon or <br />have'a 20-foot wine access to a public way Al <br />least 20 feel In width. Section 703. <br />39. <br />Light. and ventilation should comply with Section <br />705. <br />40. <br />A One-Ncur Fire-nesistive Occupancy Separation <br />Is required between the boiler or central heat• <br />ing plant and the rest of the building. Section <br />708. <br />41. <br />Exterior openings for rooms containing a boiler <br />or central heating plant should be protected <br />with three -fourths -hour lire -resistive assemblics <br />that are fixed, automatic, or setf•clesilta If to. <br />crated below openinCs in another story or it Ic%s . <br />than 10 feet from other doors or windows in <br />the some building. Section 708. <br />Group C <br />42. <br />Atmospheric separations should comply with <br />Section 802 (b). <br />' <br />43. <br />Use of rooms should be clarified. Note that <br />rooms In Divisions 1 and 2 Occupancies used <br />for dfiy care purposes and rooms used for <br />kindergarten, first, or second gmdo pupils and <br />Division 3 Deco cannot be located <br />above life first stupory. Section 802 (c). <br />44. <br />Special harard roomy. should be separated Iron <br />Other portions of the huddinit by fiat less than <br />a 0 •t• flour I ire Resistive Uccupancy srpala• <br />lion. Section L'O' (d). <br />45. <br />Ono required exit should front directly open, or <br />' <br />have A 20 foul vole access to. a public way at <br />least 2.0 feel its wadth. Section 803 (a). <br />46. <br />Sanitary lacilille'. %hould tea provided in Accord. <br />once with SMAims 1105. <br />47. <br />1 whi and •romlolahcn should comply \wth Section <br />Lob, <br />
The URL can be used to link to this page
Your browser does not support the video tag.