Laserfiche WebLink
I <br />FRANKLIN <br />ENGINEERING <br />MECHANICAL CONEiULTING <br />Wall U-value Calculation <br />625 Fourth Avcrw <br />5uitc 202 <br />Kirkland WA 95033 <br />PH 425 827-3324 <br />FA,X 425 F327-6252 <br />hvac0f rah hneig,corn <br />Layer <br />Description <br />Detail <br />R-value <br />Exterior <br />Surface <br />Moving Air <br />0,17 <br />A <br />Concrete <br />6' <br />0.78 <br />a <br />3.t2'mtl, <br />2C oc <br />R-15 <br />7.80 <br />C <br />GWB <br />SIB' <br />0.50 <br />D <br />E <br />Interior <br />Surface <br />Still Air <br />0.68 <br />1. Total Column <br />9.93 <br />2. U value, invert amount in line 1 <br />0.10 <br />`Y' :� <br />