Laserfiche WebLink
C. <br />FRANKLIN <br />ENGINEERING <br />MECHANICAL CONSULING <br />625 4th Avenuc PH 425 827-3324 <br />5uitr. 202 FAX 425 827-6252 <br />Kirkland. WA 98033 hvaciLfranklineng.com <br />Rb-7o1-037 <br />January 26, 2007 <br />RE: Intermec TI <br />75" Center LLC <br />Everett, WA <br />Heated space applies to Office space. <br />Doors (Opaque): Wood, U=0.50, default. <br />Other Roof Type 1: R-30 bait insulation on T-bar ceiling. U=0.037, calculated. <br />Other Roof Type 2 (Restrooms & Phone Data): R-30 bait insulation in metal framing, 24" <br />oc (not compressed) with GWB ceiling. U=0.076, calculated. <br />Wall Type 1 (Opaque, South & East): Concrete, min. 6" thick, furred with metal studs, 3- <br />1/2", 24" oc with R-15 bait insulation, U=0.10, calculated. <br />Wall Type 2 (Opaque, Warehouse): Metal studs, min. 5-1/2", 24" oc with R-21 bait <br />insulation, U=0.085 default. <br />Slab on Grade: No Insulation, F=0.73, default. <br />Please note that these values are minimum insulation requirements for code compliance. <br />Higher insulation values may be installed. <br />