My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1620 75TH ST SW BASE FILE 2018-01-02 MF Import
>
Address Records
>
75TH ST SW
>
1620
>
BASE FILE
>
1620 75TH ST SW BASE FILE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/30/2021 8:39:23 AM
Creation date
4/18/2017 1:08:25 AM
Metadata
Fields
Template:
Address Document
Street Name
75TH ST SW
Street Number
1620
Tenant Name
BASE FILE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
106
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
the (fcererel'N - <br />-\ <br />=ONSTRUCTIOP" <br />VV <br />everett <br />PERMIT PERMIT NO. 14404 <br />CITY HALL 2598145 <br />EVERETT. WA 98201 ElCOMBINATION %M BUILDING ❑ MECHANICAL ❑ PLUMBING <br />OWNER <br />MAIL ADDRESS CITY ZIP PHONE <br />John Fluke 1620 75th <br />Street S.E. Bldg. 9 Eveiett 98204_ <br />ARCHITECT OR DESIGNER <br />MAIL ADDRESS CITY ZIP PHONE <br />GENERAL CONTRACTOR MAIL ADDRESS CITY ZIP PHONE LICENSE F <br />Sno Valley Construction 4016 148th N.E. Redmond 98052 881-9225 <br />MECHANICAL CONTRACTOR <br />MAIL ADDRE55 CITY ZIP PHONE LICENSE E <br />SNOVAI222FV <br />PLUMBING CONTRACTOR <br />MAIL ADDRESS CITY 21P PHONE LICENSE E <br />CLASS OF WORK <br />❑ NEW ❑ ADDITION MC ALTERATION ❑REPAIR ❑DEMOLITION ❑FENCE ❑SIGN ❑ WOOD 6TOVEIFIREPLACE INSERT <br />VALUATION OF WORK. <br />% 215,000.00 <br />DESCRIBE WORK <br />Tenant Improvement <br />PROPOSED USE OF BUILDING <br />I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS <br />commercial <br />APPLICATION AND KNOW THE SAME TO BE TRUE AND <br />CD <br />LEGAL DESCRIPTION OF PROPERTY (SHOW BELOW OR ATTACH FOUR COPES) CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES <br />r. <br />GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH <br />LOT _ _ BLOCK _or _ <br />WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A <br />m <br />PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE <br />OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR <br />T <br />LOCAL LAW REGULATING CONSTRUCTION OR THE <br />M� <br />PERFORMANCE OF CONS;PRUCTION. <br />N x <br />JOB ADDRESS SI@ OFC RA UTHORIZ A ENT — ATE <br />Z % f <br />v1T1 <br />1620 75th Street S.E. Bldg. <br />9 X <br />rrnn o <br />PLUMBING <br />MECHANICAL <br />CD <br />NO. <br />TYPE OF FIXTURE OR ITEM <br />FEE <br />NO. <br />TYPE OF EQUIPMENT <br />FEE <br />4 <br />WATER CLOSET (TOILET) <br />BDOAIR <br />COND. UNITS — H.P. EA. <br />BATHTUB <br />REFRIGERATION UNITS — H.P. EA. <br />— <br />q z <br />C <br />LAVATORY(WASH BASIN) <br />8 <br />OO <br />BOILERS — H.P. EA. <br />a ti <br />f" _ <br />SHOWER <br />OAS FIRED A.C. UNITS — TONNAGE EA. <br />1 <br />v' <br />T <br />KITCHEN SINK a DISP. <br />FORCED AIR SYSTEMS — S.T.U. M EA. <br />DISHWASHER <br />WALL HEATERS — B.T.U. M <br />LAUNDRYTRAY <br />UNIT HEATERS — B.T.U. M <br />CLOTHES WASHER <br />EVAPORATIVE COOLERS <br />rn .. <br />WATER HEATER <br />CLOTHES DRYERS <br />to <br />URINAL <br />2 <br />VENTILATION FAN <br />A <br />no <br />Rp <br />DRINKING FOUNTAIN <br />RANGE HOOD <br />VT <br />FLOOR DRAIN <br />AIR HANDLING UNIT — C.F.M. <br />VACUUM BREAKERS <br />STOVE — WOOD <br />ROOF DRAINS — RAINLEADERS <br />METAL FIREPLACE & CHIMNEY <br />SINK (SERVICE — BAR. ETC.) <br />FIREPLACE INSERT <br />�1 <br />HEAT PUMP <br />Z <br />-H <br />— <br />x <br />to <br />SUB TOTAL <br />t <br />18 <br />00 <br />SUB TOTAL f <br />6 <br />0 <br />PERMIT <br />{ <br />PERMIT S <br />6 00 <br />CD <br />TOTAL FEE <br />f 18 00 <br />TOTAL FEE f <br />,�.. <br />SIDE YARD SETBACK STREET SETBACK <br />REAR YARD SETBACK <br />PLAN CHECK NUMBER PUN CHECK FEE <br />m <br />N/A N/A <br />N/A <br />65/14404 FEE 468.32 72-miEIPT NO. <br />7�l3 <br />USE ZONE LOT AREA <br />VACANT SITE <br />FEES VALUATION FEE <br />M-M <br />YES NO <br />TYPE OF CONST. OCCUPANCY GROUP <br />NC. OF DWELLING UNITS <br />V-1 Hr. B4 <br />N/A <br />BUILDING s215,000. 720 50 <br />SIZE OF BLDG. NO. OF STORIES <br />MAX. OCC. LOAD <br />18 OO <br />12,200 Sq. Ft. 1 <br />123 <br />PLUMBING <br />FIRE ZONE BASEMENT <br />MECHANICAL 6 00 <br />RIRE—SPRINKLERS <br />IREYES <br />NO <br />APPROVALS <br />BY DATE <br />OTHER <br />1, ENVIRONMENTAL CHECK LIST <br />PENALTY U.B.C. <br />SEC. 303(a) <br />2. BUILDING PLANS <br />TOTAL 744 0 <br />3. FIRE HYDRANT <br />4. FIRE PROTECTION SYSTEM <br />PERMIT VALIDATION <br />WHEN PROPERLY VALIDATED (IN THIS SPACE) THIS 17 YDW4 PE IT <br />$.GRADING <br />_ <br />be <br />B. DRAINAGE <br />_ <br />Additional Mechanical permit may require. <br />T. ENVIRONMENTAL IMPACT STATEMENT <br />8. HEALTH DISTRICT <br />- I . I . A <br />APPR. FOR ISSUANCE BY <br />APPLICATION ACC. BY PLANS CHECKED By <br />STG HWM <br />LC <br />ADDRESS TILE <br />
The URL can be used to link to this page
Your browser does not support the video tag.