Laserfiche WebLink
s�^. <br />Plan Check No. 91/27220 <br />Paga 2 of 2 <br />3. Clazing in hazardoue locetions as dafined in Section 5406(dj UBC, <br />ehall be safety glazing or tempered glase. <br />4. Showers Ln aIl occupancies ahell have a smooth, hard, non-abaorbent <br />aurface to a height of not lesa than 70 inches above the drain inlet. <br />5. Handrails ahall be 1•1/2" - 2" diameter and placed 34" minimum, 38" <br />maximum above tread noeing. They ahall be continuous the full <br />Lnngth of tha ataira. Ends ehall be returned or shall terminate in <br />newe] poats or safety terminals. <br />6. Every stalrway shall have headroom cleerance of not leae than 6 feet <br />8 inches. <br />7. There ia no footing under the end of [he beam supporting flaor <br />jolata, located next to stairs at lowar lever. <br />8. Elevations do not show stepa in foundation or viaw of lower level <br />for optional basement. <br />In order for tha procesaing of your application to continue, it will be <br />necessary to provide the Building Department with two complete new seta of <br />drawinga raflecting the corrections requested. <br />Upon reaubuittal of the drawinga, your application will he given priority <br />and plan reviov w111 recommence. <br />All of the above infor.matlon shall be oE eufficient detail and contain <br />sufficiant "information to ensure that the prapoaed atructure vill be <br />conatructed in compliance with the City Building Code. <br />Sectlona ahall be applicable to plan submitted. <br />Siucerely, <br />.leff Neilman <br />EngLneering Technician <br />JH:jtb/11-32 <br />