Laserfiche WebLink
CLARK JOHNSON PAGC IoF q <br /> CONBULTING ENGINEERS <br /> 14113-112th AVENUE N.E. <br /> BELLEVUE.WA BB004 <br /> Jena)494-7137 <br /> FAX 12001 n37-P849 <br /> December 9, 1996 Revised March 27, 1997 <br /> Jeff Dye <br /> Metco Construction <br /> 18913 Bothell-Everett Iiwy. <br /> Bothell, WA 98012 <br /> Re: Merrill Creek Phase II - Basement walls - <br /> 8' -0" "effective height". <br /> Dear Jeff, <br /> It is acceptable with this office and in conformance with the Uniform <br /> Building Code to provide the following basement wall design: <br /> 0" concrete basement wall with 04 - 12" o.c. vertical inside face <br /> (with 1" clear cover) and 04 - 10" o.c. horizontal inside face where <br /> there is 8' -0" from the top of the basement floor slah to the bottom <br /> of the floor joists above and a maximum of B' -0" from the top of the <br /> basement slab on grade to the top of the garage slab, one story <br /> above. <br /> If you have any questions please call. <br /> 9 nc�eroe�ly�, <br /> Clark Jo myon, P.E. <br /> Addendum: This letter is valid only when accompanied by the <br /> following details - 1) Typical basement wall, joist perpendicular to <br /> concrete wall, 2) Typical basement wall, joist parallel to concrete <br /> wall, 3) Foundation wall at garage slab step <br /> A,PPL1E 5 <br /> -7 4 PAK-S <br /> pll�1K✓ <br /> o tNll <br /> File 5852\6326.dnk6 'ee1f�0sn <br /> Al <br /> unw 10-22- `6 <br /> ' I <br />